Skip to content
Omnikalc

Grease interceptor sizing calculator: size a grease trap from the sink compartments

Enter the number and size of the sink compartments and the drain-down time to get the flow rate, the standard interceptor size, its grease capacity and the volume of a gravity interceptor.

Updated on
Your inputs

Value out of range

in

Value out of range

in

Value out of range

in

Value out of range

Results

Rated flow of the interceptor (standard size)

25 gpm

Total volume of the compartments
56.1 gal
Peak flow rate (75% filled, drained in the chosen time)
21.0 gpm
Grease capacity of that interceptor (2 lb per gpm)
50 lb
Volume of a gravity interceptor (30 minutes of flow)
631 gal

The grease interceptor sizing calculator gives the flow rate, the standard interceptor size and the grease capacity needed for a commercial kitchen sink from the number and size of its compartments and the drain-down time, and the volume of a gravity interceptor.

How the calculation works

  • Enter the number of compartments of the sink and the length, width and depth of one compartment.
  • Choose the drain-down time, 1 or 2 minutes, which the plumbing code or the local authority sets.
  • The calculator finds the total volume and the flow rate as 75% of the volume divided by the drain-down time.
  • It picks the next standard interceptor size in gpm, its grease capacity of 2 lb per gpm, and the volume of a gravity interceptor for 30 minutes of flow.

Example

A three-compartment sink has compartments of 20 in × 18 in × 12 in. Each holds 20 × 18 × 12 / 231 = 18.7 gal, so the total is 56.1 gal. Filled at 75% and drained in 2 minutes, the flow rate is 56.1 × 0.75 / 2 = 21.0 gpm. The next standard size is 25 gpm, which holds 50 lb of grease (2 lb per gpm). A gravity interceptor for 30 minutes of that flow would hold 631 gal.

Why it matters

The calculator helps restaurant owners, plumbers, designers and kitchen planners to size the grease trap for a new or remodeled kitchen, to prepare the plumbing permit and to compare a passive device with a gravity tank. It gives the numbers that the authority asks for in the application.

Good to know

Use all the fixtures that drain to the interceptor, and the largest flow if several sinks are connected. Install the interceptor near the fixtures, with a vented outlet, and keep it accessible for cleaning. Check the local ordinance, which can require a minimum size, a gravity interceptor or a cleaning schedule. Do not pour the grease from the fryers in the drain.

The sump pump calculator sizes pumps, the drain slope calculator gives the fall of a drain, the septic tank size calculator covers on-site wastewater and the pipe flow velocity calculator checks the flow in a pipe.

Frequently asked questions

What does a grease interceptor do?

A grease interceptor, or grease trap, is a tank or device placed in the drain of a kitchen. The wastewater slows down inside it, the fats, oils and grease float to the top and are retained, and the clearer water leaves from below. It prevents the grease from cooling and sticking in the sewer pipes, where it causes blockages and overflows, and it is required by most plumbing codes for restaurants and similar establishments.

How is the flow rate found?

The method of the Plumbing and Drainage Institute and of the plumbing codes takes the volume of the fixture, here the compartments of the sink, filled to 75% to leave room for the dishes, divided by the drain-down time of 1 or 2 minutes. The result in gpm is the flow that the interceptor must handle, and the standard sizes are 4, 7, 10, 15, 20, 25, 35, 50, 75 and 100 gpm.

What is the grease capacity?

The grease capacity is the weight of grease that the interceptor can hold before it must be cleaned. The code ratio is at least 2 lb of grease per gpm of rated flow, so a 25 gpm interceptor holds 50 lb. The interceptor should be cleaned when it contains about 25% of its capacity as grease and solids, and often every one to three months. The frequency depends on the kitchen.

When is a gravity interceptor needed?

A passive hydromechanical device under the sink is common for small flows. For large flows, a big underground gravity interceptor is used, which holds the water for a retention time such as 30 minutes, and the usual size is 750 to 2,000 gal. The volume in this calculator is the flow rate times 30 minutes, and local rules often impose their own sizes and the retention time.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.