The grease interceptor sizing calculator gives the flow rate, the standard interceptor size and the grease capacity needed for a commercial kitchen sink from the number and size of its compartments and the drain-down time, and the volume of a gravity interceptor.
How the calculation works
- Enter the number of compartments of the sink and the length, width and depth of one compartment.
- Choose the drain-down time, 1 or 2 minutes, which the plumbing code or the local authority sets.
- The calculator finds the total volume and the flow rate as 75% of the volume divided by the drain-down time.
- It picks the next standard interceptor size in gpm, its grease capacity of 2 lb per gpm, and the volume of a gravity interceptor for 30 minutes of flow.
Example
A three-compartment sink has compartments of 20 in × 18 in × 12 in. Each holds 20 × 18 × 12 / 231 = 18.7 gal, so the total is 56.1 gal. Filled at 75% and drained in 2 minutes, the flow rate is 56.1 × 0.75 / 2 = 21.0 gpm. The next standard size is 25 gpm, which holds 50 lb of grease (2 lb per gpm). A gravity interceptor for 30 minutes of that flow would hold 631 gal.
Why it matters
The calculator helps restaurant owners, plumbers, designers and kitchen planners to size the grease trap for a new or remodeled kitchen, to prepare the plumbing permit and to compare a passive device with a gravity tank. It gives the numbers that the authority asks for in the application.
Good to know
Use all the fixtures that drain to the interceptor, and the largest flow if several sinks are connected. Install the interceptor near the fixtures, with a vented outlet, and keep it accessible for cleaning. Check the local ordinance, which can require a minimum size, a gravity interceptor or a cleaning schedule. Do not pour the grease from the fryers in the drain.
Related tools
The sump pump calculator sizes pumps, the drain slope calculator gives the fall of a drain, the septic tank size calculator covers on-site wastewater and the pipe flow velocity calculator checks the flow in a pipe.