The mist eliminator sizing calculator applies the Souders-Brown equation to give the maximum gas velocity, the design velocity, the cross-section area and the vessel diameter of a gas-liquid separator or knock-out drum with a mist eliminator.
How the calculation works
- Enter the gas flow rate at the operating pressure and temperature, and the densities of the liquid droplets and of the gas.
- Choose the Souders-Brown coefficient K for the type of mist eliminator: a wire mesh pad, a vane pack, or a reduced value for fouling service.
- The calculator finds the maximum velocity v = K √[(ρL − ρV) / ρV], above which the droplets are carried over.
- It applies the design share of that velocity (usually 80%) and gives the cross-section area and the vessel diameter.
Example
A separator handles 5,000 ft³/min of gas of 0.2 lb/ft³ with droplets of 50 lb/ft³. With a wire mesh pad (K = 0.35 ft/s), the maximum velocity is 0.35 × √[(50 − 0.2) / 0.2] = 5.52 ft/s. At 80%, the design velocity is 4.42 ft/s. The area is 5,000 / 60 / 4.42 = 18.86 ft², which needs a vessel diameter of 4.90 ft. The pad would flood at 6,250 ft³/min.
Why it matters
The calculator helps process engineers, gas plant and compressor station designers, scrubber and absorber designers and students to size a knock-out drum, to check an existing separator against a new flow, and to compare mesh with vane packs. It is the first step of the sizing before detailed vendor data.
Good to know
Use the gas density at the real pressure and temperature, not at standard conditions. Keep the design velocity under the maximum and above 30% of it. Leave a clear space of at least 12 in below and above the pad. For high-pressure service or sticky liquids, reduce K according to the vendor’s guidance.
Related tools
The terminal velocity calculator covers falling objects in a fluid, the Stokes’ law calculator gives the settling of small droplets, the Reynolds number calculator checks the drag regime and the tank volume calculator sizes the liquid section.