Skip to content
Omnikalc

Mist eliminator sizing calculator: Souders-Brown gas velocity and vessel diameter

Enter the gas flow, the gas and liquid densities and the type of mist eliminator to get the Souders-Brown maximum velocity, the design velocity, the area needed and the diameter of the separator vessel.

Updated on
Your inputs
ft³/min

Value out of range

lb/ft³

Value out of range

lb/ft³

Value out of range

%

Value out of range

Results

Required cross-section area

18.86 ft²

Maximum allowable gas velocity
5.52 ft/s
Design gas velocity
4.42 ft/s
Vessel diameter
4.90 ft
Gas flow at the flooding velocity
6,250 ft³/min

The mist eliminator sizing calculator applies the Souders-Brown equation to give the maximum gas velocity, the design velocity, the cross-section area and the vessel diameter of a gas-liquid separator or knock-out drum with a mist eliminator.

How the calculation works

  • Enter the gas flow rate at the operating pressure and temperature, and the densities of the liquid droplets and of the gas.
  • Choose the Souders-Brown coefficient K for the type of mist eliminator: a wire mesh pad, a vane pack, or a reduced value for fouling service.
  • The calculator finds the maximum velocity v = K √[(ρL − ρV) / ρV], above which the droplets are carried over.
  • It applies the design share of that velocity (usually 80%) and gives the cross-section area and the vessel diameter.

Example

A separator handles 5,000 ft³/min of gas of 0.2 lb/ft³ with droplets of 50 lb/ft³. With a wire mesh pad (K = 0.35 ft/s), the maximum velocity is 0.35 × √[(50 − 0.2) / 0.2] = 5.52 ft/s. At 80%, the design velocity is 4.42 ft/s. The area is 5,000 / 60 / 4.42 = 18.86 ft², which needs a vessel diameter of 4.90 ft. The pad would flood at 6,250 ft³/min.

Why it matters

The calculator helps process engineers, gas plant and compressor station designers, scrubber and absorber designers and students to size a knock-out drum, to check an existing separator against a new flow, and to compare mesh with vane packs. It is the first step of the sizing before detailed vendor data.

Good to know

Use the gas density at the real pressure and temperature, not at standard conditions. Keep the design velocity under the maximum and above 30% of it. Leave a clear space of at least 12 in below and above the pad. For high-pressure service or sticky liquids, reduce K according to the vendor’s guidance.

The terminal velocity calculator covers falling objects in a fluid, the Stokes’ law calculator gives the settling of small droplets, the Reynolds number calculator checks the drag regime and the tank volume calculator sizes the liquid section.

Frequently asked questions

What is the Souders-Brown equation?

The Souders-Brown equation gives the maximum gas velocity at which droplets can still fall out of the gas or be caught by a mist eliminator: v = K √[(ρL − ρV) / ρV]. It comes from a balance between the drag on a droplet and its weight. The coefficient K collects the droplet size, the geometry of the device and a safety margin. Above the velocity, droplets are carried over and the separator floods.

What value of K should I use?

For a wire mesh pad in a vertical vessel, K is about 0.35 ft/s (0.107 m/s). A vane pack, which handles higher velocity and larger droplets, uses about 0.5 ft/s. For dirty, fouling or viscous service, or for pressures above about 300 psig, K is reduced, down to 0.2 ft/s or less. Always check the value given by the supplier of the mist eliminator.

Why use 80% of the maximum velocity?

A design below the flooding velocity leaves a margin for gas flow variations, for liquid loading and for uncertainty in the densities. At low velocity the mesh also loses efficiency because the droplets do not impact on the wires, so the operating range is usually 30 to 100% of the maximum velocity. The calculator gives the area at your design share and the flow at which the pad would flood.

Does it apply to horizontal vessels?

The simple vertical-flow formula is for a mesh in a vertical vessel. For a horizontal flow through a vane pack or a mesh, a higher K is allowed, and the area is the cross-section of the pad in the flow direction, not the vessel cross-section. Use the supplier’s K for the actual orientation, and add the height needed above and below the pad for good flow distribution.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.