The HDD pullback force calculator gives the net weight, the friction force, the fluid drag, the total pullback force and the ratio to the safe pull force of a pipe pulled in a horizontal directional drilling bore, from the pipe size and weight, the length of the bore and the drilling fluid.
How the calculation works
- Enter the outside diameter of the pipe, the length of the bore and the weight of the pipe with its contents or ballast water.
- Choose the drilling fluid, enter the friction coefficient of the bore wall and the safe pull force of the pipe from the manufacturer.
- The calculator finds the net weight per foot, the friction and the fluid drag, the total pullback force and the ratio to the safe pull force.
Example
A pipe of 12.75 in weighs 17.5 lb/ft and is pulled in a bore of 800 ft filled with a slurry of specific gravity 1.10. The slurry displaces 62.4 × 1.10 × π/4 × 1.0625² = 60.9 lb/ft, so the net weight is 43.4 lb/ft upward. With a friction coefficient of 0.3, the friction force is 0.3 × 43.4 × 800 = 10,406 lb. The fluid drag at 0.025 psi is π × 1.0625 × 800 × 3.6 = 9,613 lb. The total pullback force is 20,019 lb, which is 0.50 of a safe pull force of 40,000 lb.
Why it matters
The calculator helps drilling contractors, utility engineers, pipeline designers and students to size the drill rig, to check the pull on a polyethylene or steel pipe, and to compare the effect of the ballast water, of the slurry weight and of the length of the bore on the pull.
Good to know
Use a full survey profile of the bore and add the capstan effect of the curves for a final design. Keep the bore clean with a good mud program, use a swivel and a pulling head rated for the load, and measure the pull force during the installation. Do not stop the pull for a long time, because the soil can settle around the pipe and the force to restart can be much larger than the force in motion.
Related tools
The pipe flow velocity calculator checks the flow in the finished pipe, the buoyancy calculator gives the uplift of a floating pipe, the pipeline coverage calculator checks the depth of cover and the friction loss calculator estimates the head loss in the line.