Hot water recirculation calculator: loop heat loss, flow and yearly cost

Enter the length of a hot water recirculation loop, the heat loss per foot, the allowed temperature drop and the cost of energy to get the heat loss, the pump flow in gpm and the annual cost of keeping the loop hot.

Updated on
Your inputs
ft

Value out of range

Btu/h·ft

Value out of range

°F

Value out of range

h

Value out of range

$

Value out of range

Value out of range

Results

Recirculation flow

0.60 gpm

Annual cost of the heat loss

$427.05

Heat loss of the loop
3,000 Btu/h
Energy lost per year
262.8 therms

A recirculation loop gives hot water at the tap right away, but the pipes lose heat all day. The hot water recirculation calculator gives the heat loss of the loop, the pump flow needed for a given temperature drop and the annual energy cost of keeping the loop hot.

How the calculation works

  • Enter the length of the recirculation loop, which is the supply pipe and the return pipe taken together, and the heat loss per foot of the insulated pipe (about 10 to 20 Btu/h per foot for a 3/4 in pipe with 1/2 in insulation).
  • Enter the temperature drop that you accept around the loop. A typical value is 5 °F to 10 °F, so that the water at the farthest fixture stays hot.
  • Enter the hours of operation per year, the cost of fuel and the efficiency of the water heater.
  • The calculator gives the heat loss of the loop, the flow that the pump must supply, Q / (500 × ΔT) in gallons per minute, and the energy and the cost of the heat lost each year.

Example

A recirculation loop of 200 ft has a heat loss of 15 Btu/h per foot, which is 3,000 Btu/h. With a temperature drop of 10 °F, the required flow is 3,000 / (500 × 10) = 0.60 gpm. Running 8,760 hours a year, the loop loses 3,000 × 8,760 = 26.3 million Btu, or 262.8 therms. At $1.30 per therm and an 80% efficient water heater, the annual cost is $427.05.

Why it matters

The calculator helps homeowners, plumbers, building managers and engineering students to see what a recirculation loop costs, to size its pump and to see what insulation or a timer can save. It also shows that a small flow is enough, since the heat loss is small.

Good to know

Use the real heat loss of the pipe from the insulation data, and include the return pipe. Compare the cost with the water and the time that the loop saves. Use a timer or a demand control, and set the temperature of the water heater to 120 °F or as the local rule requires, with a plan against Legionella for large systems.

The water heater size calculator sizes the heater, the heat loss calculator covers the building envelope, the pipe volume calculator gives the water in the pipes and the pipe flow velocity calculator checks the speed in the loop.

Frequently asked questions

What does a recirculation loop do?

A recirculation loop keeps hot water moving through the pipes, so that hot water comes out of the tap quickly, without waiting and wasting water. A pump moves the water from the water heater around the loop and back. The cost is the heat that the pipes lose all day, which the water heater has to replace, plus the electricity of the pump.

How is the pump flow found?

The loop loses heat at a rate Q along its length. To keep the water at the farthest point near the temperature at the heater, the pump must bring enough hot water to replace that heat with a given temperature drop. The flow in gpm is Q / (500 × ΔT), where 500 is the product of the density and the specific heat of water, in Btu/h per gpm per °F. A small flow is enough.

How can the cost of recirculation be reduced?

Insulate all the supply and return pipes, since this lowers the heat loss, which is the main cost. Use a timer, a temperature control or an on-demand control to run the pump only when the hot water is needed. Shorten the loop and the branches. Use a pump that matches the low flow. A timer that stops the pump for 8 hours a night cuts the energy loss by about a third.

What are the limits of this calculator?

It uses a heat loss per foot that you must estimate from the pipe size and the insulation. It assumes a constant loss over the operating hours, and it does not include the electricity of the pump, the heat loss of the branches without circulation or the extra loss in the water heater tank. For commercial buildings, the code also asks for specific insulation and controls.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.