Skip to content
Omnikalc

Hydraulic diameter calculator: the equivalent pipe diameter of any cross-section

Choose a cross-section and enter its dimensions to get the hydraulic diameter, the hydraulic radius, the flow area, the wetted perimeter and the Reynolds number.

Updated on
Your inputs
in

Value out of range

in

Value out of range

ft/s

Value out of range

mm²/s

Value out of range

Results

Hydraulic diameter

9.600 in

Hydraulic radius
2.400 in
Flow area
96.00 in²
Wetted perimeter
40.00 in
Reynolds number
71,009
Turbulent flow

Ducts, annuli and open channels are not round, but the formulas for friction and heat transfer are written for round pipes. The hydraulic diameter calculator finds the equivalent diameter of a circular, rectangular, annular or open channel section. It gives the hydraulic diameter, the hydraulic radius, the flow area, the wetted perimeter and the Reynolds number.

How the calculation works

  • Choose the cross-section (circular, rectangular, annulus or open channel) and enter its two dimensions.
  • The calculator finds the flow area A and the wetted perimeter P, the length of the walls in contact with the fluid.
  • The hydraulic diameter is Dh = 4 A / P, and the hydraulic radius is Rh = A / P, one fourth of Dh.
  • With the mean velocity and the viscosity, it gives the Reynolds number based on Dh.

Example

An air duct of 12 in × 8 in has a flow area of 96 in² and a wetted perimeter of 40 in. The hydraulic diameter is 4 × 96 / 40 = 9.6 in, and the hydraulic radius is 2.4 in. With air at 15 ft/s and a viscosity of 15.7 mm²/s, the Reynolds number is 71,000, so the flow is turbulent.

Why it matters

The hydraulic diameter lets the pipe-flow tools be used for ducts of any shape, such as HVAC ducts, heat exchanger passages, annular gaps in wells and channels. It is the first step in finding the friction loss, the Reynolds number and the heat transfer coefficient of such a section.

Good to know

The calculator handles four simple sections. The annulus is limited to an inner diameter at most 99 % of the outer one. The open channel uses the wetted perimeter without the free surface. The Reynolds ranges for laminar and turbulent flow (2,300 and 4,000) are those of a circular pipe, and they only apply roughly to other shapes. Roughness and the real velocity profile are not included.

The Reynolds number calculator uses the diameter found here, the pipe flow velocity calculator covers flow in a round pipe, the friction loss calculator gives the pressure drop, and the duct size calculator selects an air duct.

Frequently asked questions

What is the hydraulic diameter?

It is the diameter of a circular pipe that has the same ratio of flow area to wetted perimeter as the actual cross-section, Dh = 4 A / P. It is used in the formulas for friction and heat transfer of non-circular ducts, in place of the diameter of a pipe. For a circular pipe flowing full, it is exactly the diameter.

What is the hydraulic radius?

It is Rh = A / P, the flow area divided by the wetted perimeter, so it equals Dh / 4. It is the length used in the Manning and Chézy equations for open-channel flow. For a wide, shallow channel, it is close to the depth.

Can I use the hydraulic diameter for any shape?

It works well for turbulent flow in ducts of compact shapes, such as squares, rectangles of moderate aspect ratio and annuli. In laminar flow, the friction factor of non-circular shapes differs from that of a circle (for a square duct, f = 57 / Re against 64 / Re), and for very thin rectangles or sharp corners the equivalence is less accurate.

Why is a part of a surface not counted?

Only the walls that are in contact with the liquid count. In an open channel, the free surface is not a wall, so the wetted perimeter is the width plus twice the depth. In a full pipe or duct, the whole perimeter counts.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.