Enter the dead, live, roof or snow, wind and seismic loads on a member to get the LRFD load combinations of ASCE 7, the governing load, the largest ASD combination and the net uplift.

Updated on
Your inputs
kips

Value out of range

kips

Value out of range

kips

Value out of range

kips

Value out of range

kips

Value out of range

Results

Governing LRFD load (gravity)

131.5 kips

1.4 D
70.0 kips
1.2 D + 1.6 L + 0.5 (Lr or S)
131.5 kips
1.2 D + 1.6 (Lr or S) + L
124.0 kips
1.2 D + W + L + 0.5 (Lr or S)
127.5 kips
1.2 D + E + L + 0.2 S
115.0 kips
Governing ASD load
100.25 kips
Net uplift check 0.9 D − W
25.0 kips
No net uplift under this combination

Load combinations are the sums of the loads with the safety factors that a structural member must resist. The load combinations calculator forms the LRFD combinations of ASCE 7 from the dead, live, roof or snow, wind and seismic loads, finds the governing load, the largest ASD combination and the net uplift.

How the calculation works

  • Enter the dead load D (the weight of the structure), the live load L, the roof live load or snow load (Lr or S), the wind load W and the seismic load E on the member, in the same unit.
  • The calculator forms the LRFD combinations of ASCE 7 for the strength design: 1.4D, 1.2D + 1.6L + 0.5(Lr or S), 1.2D + 1.6(Lr or S) + L, 1.2D + W + L + 0.5(Lr or S) and 1.2D + E + L + 0.2S.
  • It gives the governing combination for the gravity design, the largest ASD combination (service level) and the net uplift check 0.9D − W.
  • Use the governing LRFD load to design the member, and the net uplift to check the anchorage.

Example

A column carries D = 50 kips, L = 40 kips, Lr = 15 kips, W = 20 kips and E = 12 kips. The combinations give 1.4 × 50 = 70.0, 1.2 × 50 + 1.6 × 40 + 0.5 × 15 = 131.5, 1.2 × 50 + 1.6 × 15 + 40 = 124.0, 1.2 × 50 + 20 + 40 + 7.5 = 127.5 and 60 + 12 + 40 + 3 = 115.0 kips. The governing LRFD load is 131.5 kips. The largest ASD combination is D + 0.75L + 0.75(0.6W) + 0.75Lr = 100.25 kips. The net uplift 0.9 × 50 − 20 = 25.0 kips is positive, so there is no net uplift.

Why it matters

The calculator helps structural engineering students, designers and builders to find the design load of a column, a beam or a footing, to see which combination governs, and to check the uplift of a roof or a wall. It replaces the table of formulas of the code with a quick check.

Good to know

Use the same unit for all the loads and the same sign convention: the loads in the combinations act in the same direction for the gravity cases. For uplift, enter the wind load as the upward force. Use the factored loads only with the strength of the LRFD method, and the service loads with the ASD allowable strength.

The wind load calculator gives the wind pressure on a building, the snow load calculator gives the roof snow load, the floor load calculator covers the live loads of floors and the roof truss calculator sizes a roof structure.

Frequently asked questions

What are load combinations?

A structure is subjected to several loads, which do not all act at the same time at their maximum. The codes define combinations of the loads with factors that account for the chance that they act together. The designer checks all the combinations, and designs for the one that gives the largest effect. The factors are larger for the loads that are more uncertain, such as the live load (1.6), than for the dead load (1.2).

What is the difference between LRFD and ASD?

In load and resistance factor design (LRFD), the loads are multiplied by factors greater than 1, and the strength of the member is reduced by a factor φ. In allowable strength design (ASD), the service loads are added with smaller factors, and the strength is divided by a safety factor Ω. The calculator gives both sets, and the engineer uses the combinations of the design method in use, with the matching resistance.

Why 0.9 D in the uplift check?

When the wind or the earthquake tends to lift or overturn a structure, the dead load helps to resist it. The code then uses a reduced dead load of 0.9 D, so that the check is conservative if the dead load is lower than expected. If the result is negative, there is a net uplift, and the connections and the foundation must be designed to hold the structure down.

Is this the complete list of combinations?

No. ASCE 7 has more combinations, with the load of fluids, soil pressure, rain, ice and the vertical component of the earthquake, and the effects of the self-straining forces. The calculator covers the most common ones for a member under gravity, wind and seismic loads. Use the full list of the edition of the code that applies to your project.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.