When it rains, the water that runs off a roof, a parking lot or a field must be carried away. The rational method calculator takes a surface type, a rainfall intensity and a drainage area and gives the peak runoff flow in cubic feet per second, gallons per minute, cubic metres per second and litres per second.
How the calculation works
- Peak flow Q = C × i × A. With the intensity i in inches per hour and the area A in acres, Q comes out in cubic feet per second (cfs), since one acre-inch per hour is almost exactly 1 cfs.
- Runoff coefficient C is the share of the rainfall that runs off at the peak, from 0.95 for roofs and pavement to 0.15 for woods and farmland.
- In metric units Q (m³/s) = C × i (mm/h) × A (ha) ÷ 360.
- Conversions: 1 cfs = 448.8 gallons per minute = 0.02832 m³/s = 28.32 L/s.
Example
For a dense residential area (C = 0.70) of 5 acres with a design rainfall intensity of 2.5 in/h, the peak flow is 0.70 × 2.5 × 5 = 8.8 cfs, which is 3,960 gallons per minute or 250 litres per second. Doubling the paved share of the area would raise C and so the flow in proportion, which is why paving changes the size of drains.
Why it matters
The peak flow is the number used to size gutters, pipes, culverts, channels and pumps for stormwater. The rational method is the most common first estimate for small sites, as it needs only three inputs that are easy to find.
Good to know
The method gives a peak flow only, not a volume or a time profile. It assumes uniform rain and a steady state, and it can be too high for larger areas. Local rules may require a given return period, a minimum time of concentration and safety factors. The design of drainage should be checked by a qualified engineer.
Related tools
The culvert pipe size calculator sizes a pipe for a given flow and the rain garden calculator sizes a garden that captures runoff.