Reverse osmosis recovery and flux calculator: performance of an RO membrane system

Enter the feed and permeate flows, the feed and permeate TDS and the membrane area to get the recovery, the salt rejection, the concentrate flow and TDS and the average membrane flux.

Updated on
Your inputs
gpm

Value out of range

gpm

Value out of range

mg/L

Value out of range

mg/L

Value out of range

ft²

Value out of range

Results

Recovery

60.0 %

Salt rejection
98.0 %
Concentrate (brine) flow
8.0 gpm
Concentrate TDS
3,705 mg/L
Average permeate flux
17.3 gfd
The flux is in the usual range for brackish water

The reverse osmosis recovery and flux calculator gives the recovery, the salt rejection, the concentrate flow and TDS and the average membrane flux of an RO system from the feed and permeate flows, the TDS values and the membrane area.

How the calculation works

  • Enter the feed flow to the membranes and the permeate flow that they produce.
  • Enter the TDS of the feed water and of the permeate, in mg/L.
  • Enter the total membrane area of all the elements (a standard 8 in element has about 400 ft²).
  • The calculator finds the recovery, the salt rejection, the concentrate flow, the concentrate TDS and the flux in gallons per ft² per day.

Example

A reverse osmosis system receives 20 gpm of feed at 1,500 mg/L and produces 12 gpm of permeate at 30 mg/L, with 1,000 ft² of membrane. The recovery is 12 / 20 = 60%, and the salt rejection is 1 − 30 / 1,500 = 98%. The concentrate flow is 20 − 12 = 8 gpm, with a TDS of 1,500 × (1 − 0.60 × 0.02) / (1 − 0.60) = 3,705 mg/L. The flux is 12 × 1,440 / 1,000 = 17.3 gfd.

Why it matters

The calculator helps water treatment operators, engineers, installers and students to check the performance of an RO system from field measurements, to see the effect of the recovery on the brine concentration and to find if the flux is within the design limits. It supports the monitoring of the plant and the troubleshooting.

Good to know

Normalize the data to the temperature and the pressure when you follow the performance over time, since the flux changes with the temperature by about 3% per degree Celsius. Measure the TDS by conductivity with the right conversion factor. Check the scaling limits of the concentrate with the analysis of the feed water, and keep the recovery and the flux within the recommendations of the membrane manufacturer.

The UV disinfection dose calculator covers UV treatment, the water filtration system cost calculator covers filtration, the water softener calculator covers hardness removal and the pipe flow velocity calculator checks velocities.

Frequently asked questions

What is the recovery of an RO system?

The recovery is the fraction of the feed water that leaves the system as permeate, the clean water: Recovery = permeate flow / feed flow. A brackish water system runs at 50 to 85% depending on the water and on the scaling, a seawater system at 35 to 50%. The remaining water leaves as a concentrate, or brine, that carries the rejected salts, and a higher recovery gives a more concentrated brine.

What is the salt rejection?

The salt rejection tells how well the membrane keeps the salts out of the permeate: Rejection = 1 − permeate TDS / feed TDS. A good brackish water membrane has a rejection of 98 to 99.5%. The rejection is a property of the membrane under test conditions, and it falls with the age of the membrane, a damage or a high recovery, so the permeate TDS is a good indicator to track.

How is the concentrate TDS found?

A salt balance gives the concentrate concentration: Cc = Cf (1 − R (1 − Rej)) / (1 − R), with the recovery R and the rejection Rej. At 60% recovery and 98% rejection the brine is 2.47 times more concentrated than the feed. The brine concentration must stay below the solubility limits of the scaling salts, such as calcium carbonate, calcium sulfate and silica, or the membranes scale, and an antiscalant can help.

What is the membrane flux?

The flux is the permeate flow per unit of membrane area, in gallons per square foot per day (gfd) or liters per square meter per hour (LMH). A brackish well water system is designed at 14 to 18 gfd (24 to 31 LMH) and a surface water at 10 to 14 gfd, because a higher flux brings more fouling. 1 gfd is 1.7 LMH. A lower flux needs more membrane area but gives a longer life.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.