UV disinfection dose calculator: is your UV light strong enough?

Enter the UV irradiance, the exposure time, the lamp factor and the target to get the UV dose, the dose ratio and the maximum flow rate.

Updated on
Your inputs
mW/cm²

Value out of range

s

Value out of range

%

Value out of range

gal

Value out of range

Results

UV dose delivered

14.4 mJ/cm²

Delivers a margin above the required dose
Dose required for the target
12 mJ/cm²
Dose ratio (delivered ÷ required)
1.20
Minimum exposure time for the target
10.0 s
Maximum flow rate for the target
1.50 gpm

Ultraviolet light disinfects water without chemicals, but only if the dose is high enough. The UV disinfection dose calculator takes the UV irradiance, the exposure time, the lamp factor, the target organism and the chamber volume, and gives the UV dose delivered, the dose required, the dose ratio, the minimum exposure time and the maximum flow rate for the target.

How the calculation works

  • Enter the average UV irradiance in the water in milliwatts per square centimetre and the exposure time in seconds.
  • Enter the share of the rated lamp output you can count on. Lamps lose output with age, and a film on the quartz sleeve cuts it further, so 70 to 85 percent is common.
  • Pick the target. Each target has a dose, in millijoules per square centimetre, to reach a given log reduction.
  • The UV dose is irradiance × time × lamp factor. The calculator compares it with the target, finds the minimum exposure time and the maximum flow rate for the chamber volume.

Example

A UV chamber gives an average irradiance of 1.5 mW/cm² and holds the water for 12 seconds. With a lamp factor of 80 percent, the dose is 1.5 × 12 × 0.8 = 14.4 mJ/cm². The target is Cryptosporidium at 3 logs, which needs 12 mJ/cm², so the dose ratio is 1.2. The minimum exposure time is 12 ÷ (1.5 × 0.8) = 10 seconds, which in a 0.25 gallon chamber means a maximum flow of 1.5 gallons per minute.

Why it matters

A UV unit that runs too fast or with an old lamp can look fine while delivering a dose that is too low. Checking the dose and the flow before relying on a system, and again when the lamp ages, shows whether the water really receives the needed energy and how much margin is left.

Good to know

The calculator uses a single average irradiance and the common dose values from drinking water guidelines. The real dose varies in the chamber and depends on the water clarity and the fouling. Certified UV units are tested to a standard. Use this tool to understand the numbers, not to design or approve a drinking water treatment, and replace lamps as the maker recommends.

The water purification calculator covers other treatments, the water filtration system cost calculator sizes a filter that goes before the lamp, the water hardness calculator warns about scale on the lamp sleeve, and the pool chlorine calculator covers chemical disinfection.

Frequently asked questions

What is a UV dose?

The UV dose is the amount of ultraviolet energy that each part of the water receives, in millijoules per square centimetre. It is the irradiance in milliwatts per square centimetre multiplied by the time in seconds. Higher doses inactivate more of the organisms, and each organism needs its own dose to reach a given log reduction.

Why are the doses so different?

Bacteria and protozoa such as Cryptosporidium and Giardia are inactivated by relatively low doses of 10 to 40 mJ/cm², while some viruses need much more. Adenovirus is among the hardest, which is why dose tables for drinking water treatment are set by the most resistant target that matters.

What affects the real dose?

The clarity of the water, which is measured by its UV transmittance, the dirt on the lamp sleeve, the lamp age and the flow pattern in the chamber. Real systems are tested with biological indicators to find the dose they really deliver. A single average irradiance is only a rough value.

Does UV leave a residual?

No. UV acts only while the water passes the lamp and leaves no disinfectant in the pipes. Water can be re-contaminated after the lamp, so many systems add a filter before the lamp, to remove particles that shade microbes, and keep the downstream plumbing clean.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.