Skip to content
Omnikalc

Water-cement ratio calculator: strength, cement content and sacks per yard

Enter the specified concrete strength and the mixing water to get the required average strength, the water-cement ratio, the cement content per cubic yard and the number of sacks of cement.

Updated on
Your inputs
psi

Value out of range

lb/yd³

Value out of range

Results

Water-cement ratio (by weight)

0.466

Low ratio: durable concrete for most exposures
Required average strength f’cr
5,200 psi
Cement content
643 lb/yd³
Sacks of cement (94 lb)
6.8 sacks/yd³

The water-cement ratio is the weight of water divided by the weight of cement in a concrete mix, and it governs the strength and the durability. The water-cement ratio calculator gives the ratio, the required average strength, the cement content and the number of sacks per cubic yard.

How the calculation works

  • Enter the specified compressive strength f’c at 28 days that the design requires, for example 4,000 psi.
  • The calculator adds the overdesign required by ACI 318 to reach the required average strength f’cr (+1,000 psi below 3,000, +1,200 psi up to 5,000, and 1.1 f’c + 700 above).
  • Enter the water content per cubic yard of concrete, which depends on the slump and the maximum aggregate size (about 300 lb/yd³ for a 1-inch aggregate and a 3 to 4 in slump).
  • Read the water-cement ratio from the strength curve, the cement content (water ÷ ratio) and the number of 94 lb sacks per cubic yard.

Example

A concrete with a specified strength of 4,000 psi needs an average strength of 4,000 + 1,200 = 5,200 psi. The strength curve w/c = ln(16,956 / f’cr) / 2.534 gives a water-cement ratio of 0.466. With a water content of 300 lb/yd³, the cement content is 300 / 0.466 = 643 lb/yd³, or 6.8 sacks of 94 lb. The ratio is below 0.50, which is good for the durability.

Why it matters

The calculator helps builders, concrete suppliers, students and homeowners to estimate the cement content of a mix for a given strength, to see how much the strength depends on the water, and to understand why adding water on site weakens the concrete. It gives a base for a mix design.

Good to know

Do not add water on site to ease the placing: use a plasticizer instead. A rise of 1 in of slump from added water cuts the strength by about 150 to 250 psi. Cure the concrete for at least 7 days to reach the strength. Use the calculator for a first estimate only, and confirm the mix with the trial batches and the cylinder tests.

The concrete volume calculator gives the quantity to order, the concrete curing calculator estimates the strength gain over time, the rebar calculator covers the reinforcement and the soil compaction calculator prepares the base.

Frequently asked questions

Why does the water-cement ratio matter?

The water-cement ratio, the weight of water divided by the weight of cement, is the main factor of the strength and the durability of concrete. Following Abrams' law, the strength falls as the ratio rises, because the extra water leaves pores when it evaporates. A lower ratio gives a denser, stronger, less permeable concrete that resists freezing, de-icing salts and chemical attack.

How is the required average strength computed?

Because the strength of concrete varies from batch to batch, the mix must be designed for an average strength higher than the specified one. For the case with no history of the producer, ACI 318 uses f’c + 1,000 psi below 3,000 psi, f’c + 1,200 psi from 3,000 to 5,000 psi, and 1.10 f’c + 700 psi above 5,000 psi. The calculator uses these values.

Where does the strength curve come from?

The calculator uses an exponential fit, f = 16,956 / 12.6^(w/c), of the classic ACI 211 table of the water-cement ratio against the 28-day strength for non-air-entrained concrete: 0.41 for 6,000 psi, 0.48 for 5,000 psi, 0.57 for 4,000 psi, 0.68 for 3,000 psi. Air-entrained concrete needs a ratio about 0.06 to 0.07 lower for the same strength.

Is this a complete mix design?

No. It gives the water-cement ratio and the cement content only. A full mix design also sets the aggregates, the air, the admixtures, the slump and the trial batches. The ratio is also limited by the exposure: 0.45 for severe freezing and thaw, 0.40 with de-icing salts. Always check the maximum ratio of the local code and make test cylinders.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.