Skip to content
Omnikalc

Astigmatism vector analysis (SIA) calculator

Enter the cylinder and axis before and after surgery to get the surgically induced astigmatism with its axis, the correction index, the magnitude of error, the angle of error and the residual astigmatism, using double-angle vectors.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
D

Value out of range

°

Value out of range

D

Value out of range

°

Value out of range

Results

Surgically induced astigmatism (magnitude)

1.04 D

Axis of the induced astigmatism
175 °
Correction index (induced / target)
0.70
Under 0.9: the correction is less than the target (undercorrection)
Magnitude of error (induced − target)
-0.46 D
Angle of error
-4.7 °
A small angle of error
Residual astigmatism (difference vector, target of zero)
0.50 D

The astigmatism vector analysis calculator gives the surgically induced astigmatism, its axis, the correction index, the magnitude and angle of error and the residual astigmatism from the cylinder and axis before and after a procedure.

How the calculation works

  • Enter the cylinder and axis before surgery.
  • Enter the cylinder and axis after surgery.
  • Read the induced astigmatism and the indices.

Example

Before surgery the cylinder is 1.50 D at 90°, giving a vector (1.5 cos 180°, 1.5 sin 180°) = (−1.50, 0). After surgery it is 0.50 D at 100°, a vector (0.5 cos 200°, 0.5 sin 200°) = (−0.47, −0.17). The difference is (1.03, −0.17), a magnitude of 1.04 D and an axis of 175°. The target was 1.5 D, so the correction index is 0.70, the magnitude of error is -0.46 D, and the angle of error is -4.7°.

Why it matters

The calculator helps ophthalmology residents, surgeons who audit the results of their incisions, optometry students and researchers who report refractive results with the standard vector methods.

Good to know

The method follows the double-angle plots of Jaffe and Clayman and the analysis of Alpins, where the target induced astigmatism is the change needed to reach the target, here zero astigmatism. The induced astigmatism of a single operation varies, so surgeons use the mean of many eyes to find the personal value of the incision, and this value is then used to plan the next ones. It can be computed from keratometry on the cornea, which is the best measure of the effect of an incision, or from the refraction, which also includes the effect of the lens. Vectors of many eyes are averaged component by component, not by averaging the magnitudes, and the centroid shows the systematic effect while the scatter shows the variability. The calculator uses the plus cylinder form for both measurements, so convert a minus cylinder prescription first. The result is educational and the planning of surgery is done by the surgeon with validated tools.

The keratometry calculator gives the corneal astigmatism, the cylinder transposition calculator changes the form of a prescription, the IOL power calculator treats the power of the implant and the prism conversion calculator links prism units.

Frequently asked questions

What is surgically induced astigmatism?

It is the change in astigmatism caused by an operation, for example by the incision of a cataract surgery. It is the vector difference between the astigmatism after and before, and it is not just the difference of the two cylinders.

Why the double-angle method?

An axis of 0° and one of 180° are the same, so axes cannot be averaged or subtracted directly. Doubling the angle maps the 180° cycle of the axes on a full circle, where the cylinders add like ordinary vectors.

How are the indices read?

The correction index is the ratio of the induced astigmatism to the target, and one is perfect. The magnitude of error is the induced minus the target, negative for undercorrection, and the angle of error is the axis error of the correction.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.