Skip to content
Omnikalc

BED and EQD2 calculator (radiotherapy)

Enter the number of fractions, the dose per fraction and the alpha/beta ratios of the tumor and of a late-responding tissue to get the total dose, the biologically effective dose (BED) and the equivalent dose in 2 Gy fractions (EQD2).

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs

Value out of range

Gy

Value out of range

Gy

Value out of range

Gy

Value out of range

Results

BED for the tumor

70.13 Gy

EQD2 for the tumor

58.44 Gy

Total physical dose
55.00 Gy
BED for the late-responding tissue
105.42 Gy
EQD2 for the late-responding tissue
63.25 Gy
Late tissue sees more than the physical dose: hypofractionation raises the late effect
Late-tissue BED over tumor BED
1.503

The BED and EQD2 calculator gives the biologically effective dose and the equivalent dose in 2 Gy fractions of a radiotherapy schedule, for a tumor and for a late-responding tissue.

How the calculation works

  • Enter the number of fractions and the dose per fraction.
  • Enter the alpha/beta of the tumor and of the late tissue.
  • The calculator gives the total dose, the BED and EQD2 of each, and the ratio between them.

Example

A schedule of 20 fractions of 2.75 Gy delivers 55 Gy. For a tumor with an alpha/beta of 10 Gy, BED = 20 × 2.75 × (1 + 2.75 / 10) = 70.12 Gy and EQD2 = 70.12 / 1.2 = 58.44 Gy. For a late-responding tissue with an alpha/beta of 3 Gy, BED = 105.42 Gy and EQD2 = 63.25 Gy, which is higher than the physical dose: the shorter schedule weighs more on late effects.

Why it matters

The calculator helps radiation oncology residents, medical physicists and students who compare fractionation schedules.

Good to know

The linear-quadratic model is reliable for moderate doses per fraction, roughly 1.8 to 8 Gy, and less so beyond. It treats each fraction as independent and complete repair between fractions, which fails for short intervals below 6 hours. Time effects, such as tumor repopulation in long courses, are not included here and can be added as a separate correction. The alpha/beta values are population averages, and real patients vary. Summing doses from different courses requires care: compute the EQD2 of each course and add them for the same tissue only. This page is for education and does not replace a treatment planning system or clinical review.

The equivalent fractionation calculator finds the new dose per fraction, the monitor units calculator converts a prescription to machine output, the tumor control probability calculator models the tumor response and the normal distribution calculator gives probabilities.

Frequently asked questions

What are BED and EQD2?

The biologically effective dose (BED) is the dose that would give the same biological effect if delivered in infinitely small fractions: BED = n × d × (1 + d / (α/β)). The EQD2 re-expresses it as the dose in 2 Gy fractions with the same effect: EQD2 = BED / (1 + 2 / (α/β)).

Which alpha/beta values are used?

Common textbook values are about 10 Gy for most tumors and early-reacting tissues, 3 Gy for late-responding normal tissues such as spinal cord, lung and kidney, and about 1.5 to 4 Gy for prostate and breast cancers. Values are uncertain, so look at a range.

Can I use this for patient plans?

No. The linear-quadratic model is simplified and ignores repopulation, incomplete repair between fractions and very large doses per fraction. This tool is meant for teaching and quick checks, not for clinical decisions, which belong to the radiation oncology team.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.