Enter a reference schedule and a new number of fractions to get the dose per fraction and the total dose that give the same biologically effective dose for the tumor, and how the late-tissue effect changes.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs

Value out of range

Gy

Value out of range

Value out of range

Gy

Value out of range

Gy

Value out of range

Results

Dose per fraction for the new schedule

3.544 Gy

Total dose of the new schedule
53.16 Gy
Total dose of the reference
60.00 Gy
Tumor BED (equal in both)
72.00 Gy
Change in late-tissue BED
16.0 %
Late tissue would receive a clearly higher biological dose: reduce the total dose or the fraction size
Late-tissue BED of the new schedule
115.96 Gy
Late-tissue BED of the reference
100.00 Gy

The equivalent fractionation calculator finds the dose per fraction and the total dose of a new schedule that give the same tumor BED as a reference, and shows the change in late-tissue effect.

How the calculation works

  • Enter the reference schedule: fractions and dose per fraction.
  • Enter the new number of fractions and the two alpha/beta values.
  • The calculator gives the new dose per fraction, the total, the BED and the change in late-tissue BED.

Example

The reference is 30 × 2 Gy with an alpha/beta of 10 Gy, so BED = 60 × 1.2 = 72.00 Gy. For 15 fractions, d = 10 × (−1 + √(1 + 4 × 72 / 150)) / 2 = 3.544 Gy, a total of 53.16 Gy instead of 60.00 Gy. With a late-tissue alpha/beta of 3 Gy, the late BED rises from 100.00 to 115.96 Gy, a change of 16.0 %.

Why it matters

The calculator helps radiation oncology residents, medical physicists and students who study hypofractionation.

Good to know

The result depends strongly on the alpha/beta ratio, which is uncertain, so test a range of values. The model works best between about 1.8 and 8 Gy per fraction. Large fractions, as in stereotactic treatments, need other models. When the schedule shortens the overall treatment time, tumor repopulation is reduced, which favors the shorter course and is not counted here. In practice, doses to organs at risk are limited by dose-volume constraints, not only by the BED. Always confirm any schedule change with the treatment planning system and the clinical team.

The BED and EQD2 calculator computes the biological dose of one schedule, the monitor units calculator converts a prescription to machine output, the NTCP calculator models normal tissue complications and the tumor control probability calculator models the tumor response.

Frequently asked questions

How is the new dose per fraction found?

The BED of the reference, n1 × d1 × (1 + d1 / (α/β)), is set equal to n2 × d × (1 + d / (α/β)). This is a quadratic equation in d, whose positive solution is d = (α/β) × (−1 + √(1 + 4 × BED / (n2 × α/β))) / 2.

Why does the late-tissue effect change?

Late-responding tissues have a lower alpha/beta, so they are more sensitive to the size of each fraction. Matching the tumor BED with fewer, larger fractions raises the biological dose to late tissues, unless the total dose is reduced.

Is this a clinical tool?

No. Real hypofractionation protocols are based on trials and constraints for each organ. Use this page to understand the trade-offs, not to design a treatment.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.