Skip to content
Omnikalc

Brachytherapy point source dose calculator

Choose the isotope and enter the air kerma strength of the source, the distance and the implant time to get the initial dose rate, the dose delivered and the total dose for a permanent implant.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
U

Value out of range

cm

Value out of range

days

Value out of range

Results

Initial dose rate

0.5790 cGy/h

Total dose of a permanent implant

1,190.8 cGy

Dose delivered in the implant time
351.7 cGy
Share of the total delivered in that time
29.5 %
Mean life of the isotope
85.7 days
Initial dose rate at twice the distance
0.1447 cGy/h

The brachytherapy point source calculator gives the initial dose rate at a distance from a source, the dose delivered over a time, and the total dose of a permanent implant for iodine-125, palladium-103, cesium-131 and iridium-192.

How the calculation works

  • Choose the isotope and enter the air kerma strength in U.
  • Enter the distance and the implant time.
  • The calculator gives the initial dose rate, the total dose, the dose over the time and the mean life.

Example

An iodine-125 seed of 0.6 U has a dose-rate constant of 0.965 cGy/h/U. At 1 cm, the initial dose rate is 0.6 × 0.965 / 1² = 0.5790 cGy/h. The mean life is 59.4 / ln 2 = 85.7 days, so a permanent implant delivers 1,190.8 cGy at that point in total. After 30 days, 351.7 cGy (29.5 %) have been delivered. At 2 cm the initial rate falls to 0.1447 cGy/h.

Why it matters

The calculator helps radiation oncology and medical physics students and trainees who learn the basics of seed implants.

Good to know

The point-source approximation is acceptable beyond about 1 cm from a seed but ignores the radial dose function, the anisotropy and the effect of other seeds, which add up in a real implant. Doses from several seeds are computed by summing the contribution of each. Iridium-192 is used as a temporary source, so the implant time is chosen to deliver the prescription, while the low-energy isotopes are left in place. Do not use this tool to plan a treatment; planning requires the source data, imaging and independent verification. Radiation safety rules apply to handling any radioactive source.

The radioactive decay calculator treats general decay, the half-life calculator converts between half-life and decay constant, the inverse square law calculator shows the distance effect and the BED calculator compares fractionation.

Frequently asked questions

How is the dose rate from a point source computed?

With the TG-43 point-source approximation, the dose rate in water is Ḋ(r) = S_K × Λ / r², where S_K is the air kerma strength in U and Λ the dose-rate constant in cGy/h/U. It ignores the radial dose function and the anisotropy, which matter for precise work.

How is the dose of a permanent implant found?

The source decays while it stays, so the total dose is the initial dose rate multiplied by the mean life, 1.44 × the half-life. For iodine-125, that is about 2,050 hours.

Are the constants exact?

The dose-rate constants vary slightly with the source model and the data version. The values used here are typical, and a real plan relies on the manufacturer data and the planning system.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.