The brachytherapy point source calculator gives the initial dose rate at a distance from a source, the dose delivered over a time, and the total dose of a permanent implant for iodine-125, palladium-103, cesium-131 and iridium-192.
How the calculation works
- Choose the isotope and enter the air kerma strength in U.
- Enter the distance and the implant time.
- The calculator gives the initial dose rate, the total dose, the dose over the time and the mean life.
Example
An iodine-125 seed of 0.6 U has a dose-rate constant of 0.965 cGy/h/U. At 1 cm, the initial dose rate is 0.6 × 0.965 / 1² = 0.5790 cGy/h. The mean life is 59.4 / ln 2 = 85.7 days, so a permanent implant delivers 1,190.8 cGy at that point in total. After 30 days, 351.7 cGy (29.5 %) have been delivered. At 2 cm the initial rate falls to 0.1447 cGy/h.
Why it matters
The calculator helps radiation oncology and medical physics students and trainees who learn the basics of seed implants.
Good to know
The point-source approximation is acceptable beyond about 1 cm from a seed but ignores the radial dose function, the anisotropy and the effect of other seeds, which add up in a real implant. Doses from several seeds are computed by summing the contribution of each. Iridium-192 is used as a temporary source, so the implant time is chosen to deliver the prescription, while the low-energy isotopes are left in place. Do not use this tool to plan a treatment; planning requires the source data, imaging and independent verification. Radiation safety rules apply to handling any radioactive source.
Related tools
The radioactive decay calculator treats general decay, the half-life calculator converts between half-life and decay constant, the inverse square law calculator shows the distance effect and the BED calculator compares fractionation.