Skip to content
Omnikalc

NTCP calculator (Lyman-Kutcher-Burman)

Enter the dose, the irradiated volume fraction and the Lyman parameters TD50, m and n of an organ to get the tolerance dose for that volume, the t-value and the normal tissue complication probability.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
Gy

Value out of range

Value out of range

Gy

Value out of range

Value out of range

Value out of range

Results

Complication probability (NTCP)

15.38 %

Considerable risk in this model
Tolerance dose TD50 for this volume
24.50 Gy
t-value (dose − TD50) / (m × TD50)
-1.020
Standard deviation of the tolerance
4.41 Gy
Dose for 5 % complications at this volume
17.25 Gy
Dose for 10 % complications at this volume
18.85 Gy

The NTCP calculator applies the Lyman-Kutcher-Burman model to estimate the probability of a complication in normal tissue from the dose, the irradiated volume and the organ parameters TD50, m and n.

How the calculation works

  • Enter the dose and the fraction of the organ irradiated.
  • Enter TD50, m and n for the organ and endpoint.
  • The calculator gives the NTCP, the TD50 for the volume, the t-value and the doses for 5 % and 10 %.

Example

For the lung with TD50 = 24.5 Gy, m = 0.18 and n = 0.87, a uniform dose of 20 Gy to the whole organ gives t = (20 − 24.5) / (0.18 × 24.5) = -1.020. The NTCP is Φ(-1.020) = 15.38 %. If only half of the lung is irradiated, TD50 becomes 24.5 × 0.5^−0.87 = 44.8 Gy and the same dose gives a much lower risk. The dose for 5 % complications at the full volume is 17.25 Gy.

Why it matters

The calculator helps medical physics and radiation oncology students who learn normal tissue complication models.

Good to know

The calculator assumes uniform dose in the irradiated part. Real dose distributions are non-uniform and are first reduced to an equivalent uniform dose or an effective volume with a histogram reduction method. The parameters differ by endpoint and by fractionation, and the original Burman values are very approximate. Modern work uses updated parameters from large data sets, such as those in QUANTEC and in dedicated model reports, and constraints expressed as dose-volume limits. This page is for education only and cannot be used to judge a treatment plan.

The tumor control probability calculator models the tumor response, the BED and EQD2 calculator converts schedules, the normal distribution calculator gives the cumulative probability and the equivalent fractionation calculator adjusts the dose per fraction.

Frequently asked questions

What is the LKB model?

The Lyman-Kutcher-Burman model gives the probability of a complication as a normal cumulative distribution: NTCP = Φ((D − TD50(v)) / (m × TD50(v))). TD50 is the dose at which 50 % of patients would have the complication.

How does the volume enter?

The tolerance dose rises when only part of the organ is irradiated: TD50(v) = TD50(1) × v^−n. The parameter n describes how strong this volume effect is: near 1 for parallel organs such as lung, near 0 for serial organs such as spinal cord.

Which parameters should I use?

Burman’s classic fits give, for example, lung (TD50 24.5 Gy, m 0.18, n 0.87), kidney (28 Gy, 0.10, 0.70), liver (40 Gy, 0.15, 0.32), heart (48 Gy, 0.10, 0.35) and spinal cord (66.5 Gy, 0.175, 0.05). They depend on the endpoint and the dose per fraction and are not recommended for plans.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.