Pulse pressure variation (fluid responsiveness) calculator

Enter the highest and the lowest pulse pressure of a breathing cycle on the arterial line, and the tidal volume, to get the pulse pressure variation in percent, the mean pulse pressure and the likelihood that fluids will increase the cardiac output.

Updated on

Educational tool, not medical advice: this page does not diagnose and does not replace a doctor, nurse or pharmacist. It has not been reviewed by a healthcare professional. Editorial and medical policy

Your inputs
mmHg

Value out of range

mmHg

Value out of range

mL/kg

Value out of range

Results

Pulse pressure variation

16.7 %

13 % or more: the patient is likely to respond to fluids, with an increase of the cardiac output of 15 % or more
Mean pulse pressure over the breath
48.0 mmHg
Tidal volume condition (1: met, 0: not met)
1
The tidal volume condition is met (8 mL/kg or more)

The pulse pressure variation calculator gives the respiratory variation of the arterial pulse pressure in percent, the mean pulse pressure and the likelihood of response to fluids, with a check of the tidal volume condition.

How the calculation works

  • Enter the highest and the lowest pulse pressure over a breath.
  • Enter the tidal volume in mL/kg.
  • Read the variation and the interpretation.

Example

The pulse pressure swings between 44 and 52 mmHg. The mean is 48 mmHg and the variation is (52 − 44) / 48 = 16.7 %. This is above 13 %, so the patient is likely to respond to fluids, with a tidal volume of 8 mL/kg that meets the condition of the measure.

Why it matters

The calculator helps intensive care and anesthesia physicians, nurses with arterial line monitoring and students who learn about dynamic indices of fluid responsiveness, and who check the number displayed by a monitor.

Good to know

Michard and colleagues showed in 2000 that a variation above 13 % separated responders from non-responders in patients with septic shock on mechanical ventilation, with a high sensitivity and specificity. The same formula applies to the stroke volume variation, where the highest and lowest stroke volumes over a breath are used. Many monitors compute the value automatically from the arterial waveform. The method has well-known limits: it does not work in spontaneously breathing patients, in atrial fibrillation or frequent extra beats, with a tidal volume under 8 mL/kg or with an open chest, and it can give false positives with right heart failure. In the grey zone of 9 to 13 % about a quarter of patients cannot be classified. Other tests such as the passive leg raising or an end-expiratory occlusion test are useful in these cases. Fluid is then given in small boluses of 250 to 500 mL with a check of the effect on the cardiac output. This calculator is for education and the decision is clinical.

The potassium deficit calculator treats an electrolyte problem, the parenteral nutrition calculator plans feeding, the cardiac output calculator computes flow and the oxygen delivery calculator relates it to oxygen supply.

Frequently asked questions

What is pulse pressure variation?

During a mechanical breath the pressure in the chest changes the filling of the heart, so the pulse pressure on the arterial line rises and falls with the ventilator. The swing is larger when the heart is on the steep part of its curve, which means it will respond to fluids.

When is it reliable?

In a patient who is sedated, on a ventilator with a tidal volume of at least 8 mL/kg, in a regular rhythm and with a closed chest. It is not reliable with spontaneous breathing, arrhythmias, a low tidal volume or a high right heart pressure.

Is a response always good?

Responsiveness only says that fluids will raise the output. Whether they are needed depends on the signs of poor perfusion. Fluids given without need can cause edema and harm the lungs.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.