When a liquid or gas flows through a bed of packing, catalyst or sand, it loses pressure by friction against the particles. The Ergun equation calculator takes the superficial velocity, the bed length, the particle diameter, the void fraction, and the density and viscosity of the fluid, and gives the pressure drop over the bed and per foot, the particle Reynolds number and the share of the loss due to viscous forces.
How the calculation works
- Enter the superficial velocity of the fluid (the flow rate divided by the empty cross-section), the bed length, the particle diameter, the void fraction ε of the bed, and the density and viscosity of the fluid.
- The calculator applies the Ergun equation: ΔP / L = 150 μ (1 − ε)² u / (ε³ d²) + 1.75 ρ (1 − ε) u² / (ε³ d).
- The first term is the viscous loss (Blake–Kozeny), which dominates at low flow, and the second is the inertial loss (Burke–Plummer), which dominates at high flow.
- It gives the pressure drop over the whole bed and per foot, the particle Reynolds number and the share of viscous loss.
Example
Water flows at 0.3 ft/s through a bed 6 ft long of 1/8 in spheres with a void fraction of 0.4. The viscous term gives 7,654 Pa/m and the inertial term 43,186 Pa/m. The pressure drop is 50,840 Pa/m, which is 2.25 psi/ft, or 13.5 psi over the bed. The particle Reynolds number is 484, a transition regime, and 15 % of the loss comes from viscous forces.
Why it matters
The pressure drop of a packed bed sets the size of pumps and blowers and the energy cost of a process. Chemical engineers use the Ergun equation for fixed-bed reactors, absorption and distillation columns, filters and ion exchangers, and the calculator shows which part of the loss, viscous or inertial, matters for a given flow.
Good to know
The equation is for a uniform bed of particles of the same size, with a constant void fraction, and a fluid that does not change density (liquids, and gases with a small drop in pressure). In gases with a large pressure drop, the velocity changes along the bed. Wall effects increase the void fraction near the wall in narrow columns, and particle shape and size distribution change the result. The constants 150 and 1.75 are typical and vary for real beds.
Related tools