When a surface is heated or cooled, the heat takes time to cross a wall. The Fourier number calculator gives the dimensionless time of this process. Choose a material, a half-thickness and a time, and it gives the Fourier number, the temperature step reached at the center, the depth of heat penetration and the times to reach 50 % and 95 %.
How the calculation works
- Choose the material and enter the half-thickness of the wall (the distance from a heated surface to the center) and the time since the surfaces reached their new temperature.
- The Fourier number is Fo = α t / L², where α is the thermal diffusivity of the material, the dimensionless time of heat conduction.
- The calculator sums the first terms of the exact series for a slab with surfaces held at a new temperature to find the fraction of the step reached at the center.
- It also gives the penetration depth 2√(αt) and the times to reach 50 % and 95 % at the center.
Example
A brick wall 8 in thick (half-thickness 4 in) has both faces brought to a new temperature, and 6 h pass. The diffusivity of brick is 0.52 mm²/s, so Fo = 1.09. The center has reached 91.3 % of the step. The heat penetrates to about 8.3 in. Half of the step is reached at the center after about 2.1 h, and 95 % after 7.2 h.
Why it matters
The Fourier number is used to judge how fast a wall, a slab, a casting, a food or a pipe wall warms up or cools down, and when a time of heating is long enough to reach equilibrium. It guides the design of thermal mass in buildings, heat treatment of metals, cooking and freezing of food and the cooling of castings.
Good to know
The calculator is for one-dimensional conduction in a slab of constant properties with an initial uniform temperature and both surfaces taken to a new fixed temperature at the start. A real surface with a finite convection coefficient (a Biot number that is not very high) heats up more slowly. The diffusivity is a typical value at room temperature and changes with moisture and temperature, so the times are estimates.
Related tools
The Biot number calculator tells when the temperature inside is uniform, the heat conduction calculator gives the steady flow through a wall, Newton’s law of cooling calculator covers the lumped case, and the specific heat calculator covers the energy stored.