Skip to content
Omnikalc

Fourier number calculator: how far has heat gone into a wall after a given time?

Choose a material, enter the half-thickness and the time to get the Fourier number, the temperature reached at the center of the wall and the time to equilibrium.

Updated on
Your inputs
in

Value out of range

h

Value out of range

Results

Fourier number

1.088

The temperature profile is developed; the wall is close to equilibrium
Temperature step reached at the center
91.3 %
Heat penetration depth 2√(αt)
8.34 in
Time to reach 50 % at the center
2:05:16
Time to reach 95 % at the center
7:14:11

When a surface is heated or cooled, the heat takes time to cross a wall. The Fourier number calculator gives the dimensionless time of this process. Choose a material, a half-thickness and a time, and it gives the Fourier number, the temperature step reached at the center, the depth of heat penetration and the times to reach 50 % and 95 %.

How the calculation works

  • Choose the material and enter the half-thickness of the wall (the distance from a heated surface to the center) and the time since the surfaces reached their new temperature.
  • The Fourier number is Fo = α t / L², where α is the thermal diffusivity of the material, the dimensionless time of heat conduction.
  • The calculator sums the first terms of the exact series for a slab with surfaces held at a new temperature to find the fraction of the step reached at the center.
  • It also gives the penetration depth 2√(αt) and the times to reach 50 % and 95 % at the center.

Example

A brick wall 8 in thick (half-thickness 4 in) has both faces brought to a new temperature, and 6 h pass. The diffusivity of brick is 0.52 mm²/s, so Fo = 1.09. The center has reached 91.3 % of the step. The heat penetrates to about 8.3 in. Half of the step is reached at the center after about 2.1 h, and 95 % after 7.2 h.

Why it matters

The Fourier number is used to judge how fast a wall, a slab, a casting, a food or a pipe wall warms up or cools down, and when a time of heating is long enough to reach equilibrium. It guides the design of thermal mass in buildings, heat treatment of metals, cooking and freezing of food and the cooling of castings.

Good to know

The calculator is for one-dimensional conduction in a slab of constant properties with an initial uniform temperature and both surfaces taken to a new fixed temperature at the start. A real surface with a finite convection coefficient (a Biot number that is not very high) heats up more slowly. The diffusivity is a typical value at room temperature and changes with moisture and temperature, so the times are estimates.

The Biot number calculator tells when the temperature inside is uniform, the heat conduction calculator gives the steady flow through a wall, Newton’s law of cooling calculator covers the lumped case, and the specific heat calculator covers the energy stored.

Frequently asked questions

What is the Fourier number?

It is Fo = α t / L², the dimensionless time in a heat conduction problem. It compares the time that has passed with the time heat needs to diffuse over the length L. For Fo well below 0.1, the heat has not crossed the body, and for Fo above about 1 the body is nearly at the new equilibrium.

What is the thermal diffusivity?

It is α = k / (ρ c), the conductivity divided by the volumetric heat capacity. A high value (copper, aluminum) means that temperature changes spread fast, and a low value (wood, brick, glass) means they spread slowly. This is why metals feel cold, but a wall of brick takes hours to warm up.

How does it relate to the Biot number?

The Biot number tells if the temperature inside a body is uniform (Bi below 0.1, the lumped model), and the Fourier number tells how far a transient has progressed. For the exact charts of transient conduction, both are needed. This calculator assumes that the surface temperature changes at once, which is the case of a very high Biot number.

What are the limits of the series?

The one-term approximation is good for Fo above about 0.2, and the four terms used here are accurate also at lower values, down to Fo of about 0.05. At very low Fo, the problem is that of a semi-infinite solid, and the depth of heat penetration of 2√(αt) is a better guide.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.