Skip to content
Omnikalc

Can you treat a hot object as one uniform temperature?

Choose a shape and enter its size, the convection coefficient and the material properties: get the Biot number, the characteristic length and the cooling time constant.

Updated on
Your inputs

Value out of range

W/(m²·K)

Value out of range

W/(m·K)

Value out of range

kg/m³

Value out of range

J/(kg·K)

Value out of range

Results

Biot number

0.00463

Bi under 0.1: the body stays nearly uniform in temperature, so the lumped capacitance model is valid
Characteristic length (volume ÷ surface)
8.33 mm
Time constant of the lumped model
1,282 s
Time constant in minutes
21.4 min
Time to reach 95% of the temperature change
64.0 min

A hot steel ball dropped in water does not cool evenly: the surface cools first and the core follows. Whether this difference matters depends on one number, the Biot number. It compares how easily heat moves inside the body with how easily it leaves through the surface. If heat moves inside much more easily, the body can be treated as one lump at one temperature, a big simplification. This calculator gives the Biot number, the characteristic length and, if the lumped model holds, the time constant of the cooling.

How the calculation works

  • Characteristic length Lc = volume ÷ surface area
  • Biot number Bi = h × Lc ÷ k
  • Time constant τ = ρ × c × Lc ÷ h
  • Time to reach 95% of the change ≈ 3 × τ
  • Lc is r ÷ 3 for a sphere, r ÷ 2 for a cylinder, half the thickness for a plate and side ÷ 6 for a cube

Example

A steel sphere of radius 25 mm (k = 45 W/m·K, density 7,850 kg/m³, specific heat 490 J/kg·K) cools in air with h = 25 W/m²·K. Lc = 25 ÷ 3 = 8.33 mm, and Bi = 25 × 0.00833 ÷ 45 = 0.0046, far below 0.1. The lumped model is valid. The time constant is 1,282 s, about 21 minutes, and the sphere reaches 95% of its final temperature change in about 64 minutes.

Why it matters

Engineers use the Biot number as a quick test before choosing how to model heat transfer. In heat treatment, food cooling, electronics and fire safety, a small Biot number allows a simple equation, while a large one calls for far more detailed calculations. It also shows why thick, poorly conducting materials such as concrete or a roast need a numerical approach.

Good to know

The Biot number is not the Nusselt number, even though both use h and a length: Biot uses the conductivity of the solid, Nusselt that of the fluid. The convection coefficient h is the hard part, since it depends on the flow and the surface, so the result is only as good as that estimate. Radiation is not included, and it can matter at high temperatures.

The heat conduction calculator gives the heat flow through a wall, the specific heat calculator relates energy and temperature, and the Reynolds number calculator helps estimate the flow regime that sets h.

Frequently asked questions

What is the Biot number?

A dimensionless number that compares the resistance to heat flow inside a body with the resistance at its surface: Bi = h × Lc ÷ k. A small Bi means the body is thermally uniform and cools or heats as a whole.

What is the characteristic length?

The volume divided by the surface area exposed to the fluid. It equals r ÷ 3 for a sphere, r ÷ 2 for a long cylinder, the half-thickness for a plate cooled on both faces and the side ÷ 6 for a cube.

When can I use the lumped capacitance method?

When Bi is below about 0.1. The temperature then varies by less than 5% across the body and the simple exponential law T(t) applies, with the time constant τ = ρ × c × Lc ÷ h.

What if the Biot number is large?

Then the surface cools much faster than the core. You need the transient conduction solutions, such as the Heisler charts or a numerical simulation, because temperature varies strongly inside the body.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.