A hot steel ball dropped in water does not cool evenly: the surface cools first and the core follows. Whether this difference matters depends on one number, the Biot number. It compares how easily heat moves inside the body with how easily it leaves through the surface. If heat moves inside much more easily, the body can be treated as one lump at one temperature, a big simplification. This calculator gives the Biot number, the characteristic length and, if the lumped model holds, the time constant of the cooling.
How the calculation works
- Characteristic length Lc = volume ÷ surface area
- Biot number Bi = h × Lc ÷ k
- Time constant τ = ρ × c × Lc ÷ h
- Time to reach 95% of the change ≈ 3 × τ
- Lc is r ÷ 3 for a sphere, r ÷ 2 for a cylinder, half the thickness for a plate and side ÷ 6 for a cube
Example
A steel sphere of radius 25 mm (k = 45 W/m·K, density 7,850 kg/m³, specific heat 490 J/kg·K) cools in air with h = 25 W/m²·K. Lc = 25 ÷ 3 = 8.33 mm, and Bi = 25 × 0.00833 ÷ 45 = 0.0046, far below 0.1. The lumped model is valid. The time constant is 1,282 s, about 21 minutes, and the sphere reaches 95% of its final temperature change in about 64 minutes.
Why it matters
Engineers use the Biot number as a quick test before choosing how to model heat transfer. In heat treatment, food cooling, electronics and fire safety, a small Biot number allows a simple equation, while a large one calls for far more detailed calculations. It also shows why thick, poorly conducting materials such as concrete or a roast need a numerical approach.
Good to know
The Biot number is not the Nusselt number, even though both use h and a length: Biot uses the conductivity of the solid, Nusselt that of the fluid. The convection coefficient h is the hard part, since it depends on the flow and the surface, so the result is only as good as that estimate. Radiation is not included, and it can matter at high temperatures.
Related tools
The heat conduction calculator gives the heat flow through a wall, the specific heat calculator relates energy and temperature, and the Reynolds number calculator helps estimate the flow regime that sets h.