Skip to content
Omnikalc

Injection molding clamp force calculator: how many tons does your molding machine need?

Enter the projected area, the cavities and the cavity pressure to get the clamp force and the machine size for an injection mold.

Updated on
Your inputs
in²

Value out of range

Value out of range

%

Value out of range

psi

Value out of range

%

Value out of range

Results

Recommended machine clamp force

253 US tons

Total projected area
92.0 in²
Clamp force needed at the cavity pressure
230 US tons
Recommended clamp force in kilonewtons
2,251 kN

A molten plastic injected into a mold pushes the two halves apart, and the machine must hold them shut. The injection molding clamp force calculator takes the projected area of a part, the number of cavities, the runner allowance, the cavity pressure and a safety margin, and gives the clamp force needed, the recommended machine clamp force, the total projected area and the force in kilonewtons.

How the calculation works

  • Enter the projected area of one part, meaning the area seen in the direction of the mold opening, and the number of cavities.
  • Add an allowance for the runner and gates, usually 10 to 20 %, since they also see pressure and push the mold open.
  • Enter the average cavity pressure, which is about 4,000 to 8,000 psi for most thermoplastics and higher for thin walls and long flow paths.
  • The clamp force is the pressure times the total projected area. Add a safety margin to pick the size of the machine.

Example

A part with a projected area of 20 in² is molded in a 4-cavity mold. With 15 % for the runner, the total area is 20 × 4 × 1.15 = 92 in². At 5,000 psi in the cavity, the clamp force is 5,000 × 92 = 460,000 lbf, or 230 US tons. With a 10 % margin, the machine needs about 253 US tons, or 2,251 kN.

Why it matters

Choosing a machine that is too small causes flash, and one that is too large wastes money and energy, so the clamp force is one of the first numbers in the quote for a mold. The calculation also helps to see how many cavities a given machine can run, and the effect of a part of larger area or of a higher pressure.

Good to know

The calculator uses an average cavity pressure for the whole projected area, while the real pressure is not uniform and peaks near the gate. Side actions, slides and lifters can add forces. The pressure depends on the material, the wall thickness, the temperature and the injection speed, and a mold flow simulation gives better numbers. Treat the result as a first sizing.

The punch force calculator covers forming and cutting tonnage, the hydraulic press calculator gives the force of a cylinder, the metal weight calculator finds the mass of mold steel, and the heat conduction calculator covers heat flow through the mold.

Frequently asked questions

What is clamp force in injection molding?

It is the force that holds the two halves of the mold closed against the pressure of the molten plastic in the cavities. If the clamp force is too low, the plastic pushes the mold open and leaks out as flash on the parting line. The machine rating is given in tons, kilonewtons or tonnes-force.

What is the projected area?

It is the area of the part seen from the direction in which the mold opens, which is the area on which the cavity pressure pushes the halves apart. A deep cup has a small projected area, while a flat panel has a large one. Add the area of the runner system and gates, since they carry pressure too.

What cavity pressure should I use?

It depends on the material, the wall thickness and the flow length. Easy-flowing resins in thick parts may need 2,000 to 4,000 psi, typical parts 4,000 to 8,000 psi, and thin-wall parts with long flow paths 10,000 psi or more. A rule of thumb is 2 to 5 tons of clamp force per square inch of projected area. The material supplier gives data.

Why add a safety margin?

Pressure peaks during filling and packing can exceed the average, and a machine used at its limit wears faster and flashes more. A margin of 10 to 20 % is usual. A mold also needs enough platen size, tie-bar spacing, shot size and opening stroke, so the clamp force is only one of the checks when you choose a machine.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.