The longest step of an injection molding cycle is waiting for the plastic to cool enough to be ejected, and it depends mostly on the wall thickness. The injection molding cooling time calculator takes the plastic, the wall thickness and the melt, mold and ejection temperatures, with the other cycle time, and gives the cooling time, the total cycle time, the shots per hour, the share of the cycle spent cooling and the cooling time for a wall 25 % thicker.
How the calculation works
- Choose the plastic, which sets a typical thermal diffusivity, and enter the wall thickness of the part.
- Enter the melt temperature, the mold wall temperature and the ejection temperature, at which the part is stiff enough to leave the mold.
- The cooling time of a flat wall is t = h² / (π² α) × ln[ (4/π) × (Tmelt − Tmold) / (Teject − Tmold) ].
- Enter the other cycle time to get the total cycle, the shots per hour and the share of the cycle spent cooling.
Example
An ABS part has a wall of 0.1 in (2.54 mm), melt at 446 °F, mold at 122 °F and ejection at 203 °F. The log term is ln(4/π × 324 / 81) = 1.628, and the cooling time is 2.54² / (π² × 0.10) × 1.628 = 10.6 s. With 12 s for the rest of the cycle, the cycle is 22.6 s, which is 159 shots per hour, and cooling takes 47 % of it. A wall 25 % thicker would need 16.6 s.
Why it matters
Cooling time drives the cost of a molded part, so designers try to keep walls thin and even and processors tune temperatures. A quick estimate helps to quote a cycle time, to compare materials and wall designs, and to see how much a thickness reduction could save before the mold is cut.
Good to know
The thermal diffusivity values are typical and round, and real materials vary with grade, filler and temperature. The formula covers a flat wall cooled on both sides and ignores ribs, bosses, the cooling channel layout, the fill and pack time, the contact resistance and the change of properties with temperature. Mold flow software and trials give the actual cooling time.
Related tools
The heat conduction calculator covers heat flow through a solid, the latent heat calculator covers phase changes, the heat sink calculator sizes cooling, and the thermal expansion calculator covers dimension changes with temperature.