Skip to content
Omnikalc

Linear regulator calculator: power dissipation, efficiency, junction temperature and maximum current

Enter the input and output voltages, the load current, the thermal resistance and the ambient temperature to get the heat, the efficiency and the junction temperature.

Updated on
Your inputs
V

Value out of range

V

Value out of range

A

Value out of range

mA

Value out of range

°C

Value out of range

°C/W

Value out of range

°C

Value out of range

Results

Power dissipated as heat

1.25 W

Efficiency of the regulator
54.5 %
Junction temperature
90.2 °C
Comfortable margin below the maximum
Highest load current for the maximum junction temperature
0.52 A
Highest thermal resistance allowed (junction to ambient)
67.8 °C/W

A linear regulator keeps its output voltage by turning the excess voltage into heat. The linear regulator calculator gives the power dissipated, the efficiency, the junction temperature, the highest load current and the highest thermal resistance allowed for a given input, output, load and ambient temperature.

How the calculation works

  • Enter the input voltage, the output voltage and the load current of the linear regulator (a 7805 or an LDO, for example).
  • Enter the quiescent current of the regulator, found in its data sheet, and the ambient temperature.
  • Enter the thermal resistance from the junction to the ambient air (with or without a heat sink) and the maximum junction temperature.
  • The calculator gives the power dissipated P = (Vin − Vout) × Iload + Vin × Iq, the efficiency, the junction temperature Tj = Ta + P × θJA, the highest load current and the highest thermal resistance that keep the chip under its limit.

Example

A regulator converts 9 V into 5 V for a load of 0.3 A, with a quiescent current of 6 mA. The power dissipated is (9 − 5) × 0.3 + 9 × 0.006 = 1.25 W, and the efficiency is 5 × 0.3 / (9 × 0.306) = 54.5 %. In air at 40 °C with a thermal resistance of 40 °C/W, the junction temperature is 40 + 1.254 × 40 = 90.2 °C. The regulator can give up to 0.52 A before it reaches 125 °C.

Why it matters

The calculator helps electronics students, makers and engineers to check if a 7805, an LDO or another linear regulator will survive in a design, and to size a heat sink. It shows the heat before the circuit is built, which prevents thermal shutdowns, short life and burns.

Good to know

The thermal resistance depends on the package, the copper area of the board, the heat sink and the air flow, so use the value of your design from the data sheet or a measurement. The calculation is for a steady load and a steady temperature. Short peaks of current are filtered by the thermal mass, but they can trigger the protection of the chip. The case and the heat sink must be cooler than the junction.

The buck converter calculator designs an efficient step-down converter, the boost converter calculator handles step-up converters, the LED resistor calculator sizes a series resistor that also dissipates heat, and the heat sink calculator sizes the cooling of a power part.

Frequently asked questions

Why does a linear regulator get hot?

A linear regulator acts like a variable resistor in series with the load, and it keeps the output voltage by burning the difference between the input and the output as heat. The power lost is (Vin − Vout) × I. A 7805 that drops 12 V to 5 V at 1 A dissipates 7 W, which is too much for the chip without a large heat sink.

What is the efficiency of a linear regulator?

The efficiency is close to Vout / Vin, since the current in and out is almost the same. A regulator from 9 V to 5 V is about 55 % efficient, and one from 12 V to 3.3 V is only 27 %. A switching regulator, such as a buck converter, reaches 85 to 95 % and is better when the difference between the voltages is large or the power is high.

How is the junction temperature computed?

The junction temperature is the ambient temperature plus the dissipated power multiplied by the thermal resistance from the junction to the ambient air. A TO-220 package without a heat sink has about 50 °C/W, and with a small heat sink it can reach 20 to 30 °C/W. The data sheet gives the maximum junction temperature, usually 125 or 150 °C.

When is an LDO a better choice?

A low-dropout regulator works with an input only a few hundred millivolts above the output, which reduces the dissipated power and keeps the efficiency high. It is a good choice for a small voltage drop, a low noise supply or a low current. For a large drop with a high current, a switching converter or a pre-regulator to lower the input voltage is better.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.