Surface tension wants to make a drop round, inertia wants to break it up, and viscosity damps both. The Ohnesorge number calculator gives the weight of viscosity from the liquid, the diameter and, for the related numbers, the velocity. It gives the Ohnesorge, Weber and Reynolds numbers and the properties used.
How the calculation works
- Choose the liquid and enter the diameter of the drop or jet and its velocity.
- The Ohnesorge number is Oh = μ / √(ρ σ L), the ratio of viscous forces to the geometric mean of inertia and surface tension. It does not depend on velocity.
- The calculator also gives the Weber number We = ρ V² L / σ and the Reynolds number Re = ρ V L / μ, with the link Oh = √We / Re.
- Low Oh means that viscosity is not important, and high Oh means that it damps the breakup.
Example
A water drop 1 mm across moves at 5 m/s. The Ohnesorge number is 0.0037, so viscosity is negligible. The Weber number is 343, far above 12, and the Reynolds number is 4,980. The impact energy is much larger than the surface energy, so the drop splashes or breaks up on impact.
Why it matters
Spray and drop physics is used in inkjet printing, engines, paint, medicine inhalers, spray cooling and crop spraying. The Ohnesorge number is the quick way to know if the liquid is thin enough for a fine spray or too viscous, and the Weber number tells if a drop is going to splash.
Good to know
The properties are typical values at 68 °F (20 °C) for five liquids, and they change with temperature and with additives (surfactants, polymers). The thresholds of 0.1 and 1 for Oh and 1 and 12 for We are guidelines, as the transitions depend on the geometry and on the process, such as a free jet, an impact on a solid or an air-assisted spray.
Related tools
The Weber number calculator covers the ratio of inertia to surface tension, the Reynolds number calculator covers inertia against viscosity, the capillary rise calculator covers surface tension in a tube, and the Stokes’ law calculator covers viscous drag on a small sphere.