Skip to content
Omnikalc

Ohnesorge number calculator: does viscosity control the breakup of your drop or jet?

Choose a liquid, then enter the diameter and velocity to get the Ohnesorge, Weber and Reynolds numbers and a note on how the drop or jet will behave.

Updated on
Your inputs
mm

Value out of range

m/s

Value out of range

Results

Ohnesorge number

0.0037

Low viscosity: inertia and surface tension control the breakup
Weber number
342.7
Inertia exceeds surface tension: the drop can splash or break up
Reynolds number
4,980.0
Viscosity used
1.002 mPa·s
Surface tension used
72.8 mN/m

Surface tension wants to make a drop round, inertia wants to break it up, and viscosity damps both. The Ohnesorge number calculator gives the weight of viscosity from the liquid, the diameter and, for the related numbers, the velocity. It gives the Ohnesorge, Weber and Reynolds numbers and the properties used.

How the calculation works

  • Choose the liquid and enter the diameter of the drop or jet and its velocity.
  • The Ohnesorge number is Oh = μ / √(ρ σ L), the ratio of viscous forces to the geometric mean of inertia and surface tension. It does not depend on velocity.
  • The calculator also gives the Weber number We = ρ V² L / σ and the Reynolds number Re = ρ V L / μ, with the link Oh = √We / Re.
  • Low Oh means that viscosity is not important, and high Oh means that it damps the breakup.

Example

A water drop 1 mm across moves at 5 m/s. The Ohnesorge number is 0.0037, so viscosity is negligible. The Weber number is 343, far above 12, and the Reynolds number is 4,980. The impact energy is much larger than the surface energy, so the drop splashes or breaks up on impact.

Why it matters

Spray and drop physics is used in inkjet printing, engines, paint, medicine inhalers, spray cooling and crop spraying. The Ohnesorge number is the quick way to know if the liquid is thin enough for a fine spray or too viscous, and the Weber number tells if a drop is going to splash.

Good to know

The properties are typical values at 68 °F (20 °C) for five liquids, and they change with temperature and with additives (surfactants, polymers). The thresholds of 0.1 and 1 for Oh and 1 and 12 for We are guidelines, as the transitions depend on the geometry and on the process, such as a free jet, an impact on a solid or an air-assisted spray.

The Weber number calculator covers the ratio of inertia to surface tension, the Reynolds number calculator covers inertia against viscosity, the capillary rise calculator covers surface tension in a tube, and the Stokes’ law calculator covers viscous drag on a small sphere.

Frequently asked questions

What is the Ohnesorge number?

It is Oh = μ / √(ρ σ L), a dimensionless number that relates viscous forces to inertial and surface tension forces. It depends only on the liquid properties and the size, not on the speed. It is named after Wolfgang von Ohnesorge, who studied the atomization of liquid jets in 1936.

How is it related to the Weber and Reynolds numbers?

Oh = √We / Re. The Weber number says how much inertia exceeds surface tension, the Reynolds number says how much inertia exceeds viscosity, and the Ohnesorge number removes the speed and compares viscosity with surface tension. A map of Oh against Re (the Ohnesorge diagram) shows the regimes of jet breakup.

What do the values mean?

For Oh below 0.1, viscosity has little effect, and drops and jets break up by inertia and surface tension, giving the fast and fine sprays of water or fuel. Above about 1, viscosity damps the oscillations, jets become long ligaments, and larger drops form, as with honey or glycerol.

Where is it used?

In inkjet printing (a stable drop needs an Oh in a range of about 0.1 to 1), fuel injection, spray coating, spray drying, agricultural sprays, atomizers and the splash of drops on a surface. Printable inks are tuned for the right Oh and We.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.