An amplifier cannot change its output voltage infinitely fast. The slew rate calculator gives the slew rate required for a sine wave of a given amplitude and frequency, compares it with the slew rate of the op amp, and gives the margin, the full-power bandwidth and the largest undistorted amplitude.
How the calculation works
- Enter the peak amplitude of the output signal, its frequency and the slew rate of the op amp from its datasheet.
- The steepest slope of a sine wave Vp sin(2π f t) is 2π f Vp. This is the required slew rate.
- If the op amp slew rate is lower than this, the output cannot follow and the wave is distorted.
- The calculator also gives the margin, the full-power bandwidth FPBW = SR / (2π Vp) and the largest undistorted amplitude at the frequency.
Example
An audio op amp with a slew rate of 9 V/µs must output a 10 V peak sine wave at 20 kHz. The required slew rate is 2π × 20,000 × 10 = 1.257 V/µs. The margin is 7.162, so there is no slew-rate distortion. The full-power bandwidth is 143.2 kHz.
Why it matters
Slew-rate limiting is one of the main causes of distortion in op amp circuits that handle large signals at high frequencies, such as audio power stages, filters, instrumentation and pulse circuits. A quick check with this formula avoids choosing an op amp that cannot follow the signal.
Good to know
The calculator applies to a sinusoidal output and to the slew rate in a single direction, and the slew rate of a real op amp can differ for rising and falling edges, and depends on the load, the supply voltage and the temperature. For a square wave or a pulse, the rise time is what matters, and a step of ΔV takes ΔV/SR to complete. The undistorted amplitude shown is limited by the slew rate only, and the supply voltage or the output swing may be smaller.
Related tools
The op-amp gain calculator gives the closed-loop gain whose bandwidth also limits the signal, the RC filter calculator covers the filters built around the op amp, the Nyquist sampling calculator covers the rate of the converters that follow it, and the total harmonic distortion calculator measures the distortion that a low slew rate produces.