A cylinder in a flow sheds vortices at a regular frequency, and this can make a wire sing or a chimney sway. The Strouhal number calculator finds the vortex shedding frequency from the fluid, the flow speed and the diameter, with the Roshko correlation. It gives the Strouhal number, the Reynolds number, the period and the ratio to the natural frequency of the structure.
How the calculation works
- Choose the fluid (air or water) and enter the flow speed, the diameter of the cylinder and the natural frequency of the structure.
- The calculator finds the Reynolds number Re = U D / ν, then the Strouhal number from the Roshko fit St = 0.198 (1 − 19.7 / Re).
- The shedding frequency is f = St × U / D, the frequency at which vortices leave alternate sides of the cylinder.
- It compares this frequency with the natural frequency to warn of a possible resonance, known as lock-in.
Example
Air blows at 30 mph (13.4 m/s) across a cable or pole of 1 in diameter. The Reynolds number is 22,710 and the Strouhal number is 0.198. The vortices shed at 104.5 Hz, a period of 9.6 ms. With a natural frequency of 150 Hz, the ratio is 0.70, so the structure is away from resonance.
Why it matters
Flow-induced vibration is a design problem for chimneys, antenna masts, power lines, cable-stayed bridges, heat exchanger tubes, thermowells and offshore risers. A quick calculation of the shedding frequency shows when a resonance can happen, and it explains the humming tone of a wire in the wind (the Aeolian tone).
Good to know
The correlation is for a smooth, circular, stationary cylinder in a steady and uniform flow, between Reynolds numbers of about 47 and 200,000, with a fixed viscosity for air and water at 68 °F (20 °C). Other shapes have other Strouhal numbers (a square section about 0.13, a flat plate about 0.15), and roughness, turbulence, end effects and a nearby wall change the value. Use it as a first screening, not as a design check.
Related tools
The Reynolds number calculator gives the flow regime that sets the shedding, the drag force calculator gives the mean load, the pipe resonance calculator covers standing waves in a pipe, and the Mach number calculator covers the speed of compressible flow.