Skip to content
Omnikalc

Theis drawdown calculator: how far does the water level fall around a pumped well?

Enter the pumping rate, the transmissivity, the storativity, the distance and the time to get the drawdown from the Theis equation and the Cooper–Jacob approximation.

Updated on
Your inputs
gpm

Value out of range

ft²/day

Value out of range

Value out of range

ft

Value out of range

days

Value out of range

Results

Drawdown at the distance r

3.63 ft

Cooper–Jacob approximation of the drawdown
3.63 ft
Well function argument u
0.00150
A small u: the Cooper–Jacob approximation also holds
Well function W(u)
5.927

When a well is pumped, the water level around it falls, and the fall grows with time and shrinks with the distance. The Theis drawdown calculator takes the pumping rate, the transmissivity, the storativity, the distance and the time, and gives the drawdown from the Theis equation, the Cooper–Jacob approximation, the argument u and the well function W(u).

How the calculation works

  • Enter the pumping rate, the transmissivity and the storativity of the aquifer, the distance from the pumped well to the point of interest and the time since pumping started.
  • The calculator finds the argument u = r² S / (4 T t), which combines the geometry and the aquifer properties with time.
  • It then evaluates the well function W(u), the exponential integral, with a series, and applies the Theis equation: s = Q / (4π T) × W(u).
  • It also gives the Cooper–Jacob approximation, s = Q / (4π T) × (−0.5772 − ln u), which is valid when u is below about 0.05.

Example

A well pumps at 200 gpm (1,090 m³/day) from an aquifer with a transmissivity of 5,000 ft²/day (464.5 m²/day) and a storativity of 0.001. At 300 ft (91.4 m) from the well, after 3 days, u = 91.44² × 0.001 / (4 × 464.5 × 3) = 0.0015. The well function is W = 5.927, and the drawdown is 1,090 / (4π × 464.5) × 5.927 = 1.107 m, which is 3.63 ft. The Cooper–Jacob approximation gives the same value, 3.63 ft.

Why it matters

Pumping tests are the main way to learn the properties of an aquifer, and the Theis equation is the base for planning a well field, checking if neighbouring wells interfere, and estimating the effect of drawdown on streams and wetlands. The calculator lets students and engineers see how the pumping rate, the time and the distance change the drawdown.

Good to know

The equation is for an ideal confined aquifer. Real aquifers have limits, leakage, layering and wells that are not ideal, and a pumping test is analysed with a type curve or a model. The series for W(u) is accurate for u up to about 3, and the calculator caps u at 3 beyond that, where the drawdown is already negligible. Use it for estimates and not for the design of a water supply.

The well drawdown calculator covers the steady state around a well, the Darcy’s law calculator gives the flow through a porous medium, the reference evapotranspiration calculator covers a water loss to the atmosphere, and the peak flow calculator covers the flood runoff of a catchment.

Frequently asked questions

What is the Theis equation?

It describes how the water level (the head) falls around a well that is pumped at a constant rate from a confined aquifer, with time and with the distance from the well. Theis found it in 1935 by analogy with the flow of heat. The drawdown is given by Q / (4πT) times the well function W(u), which is the exponential integral.

What are transmissivity and storativity?

Transmissivity T is the rate at which water flows through the full thickness of the aquifer for a unit head gradient, equal to the hydraulic conductivity times the thickness. Storativity S is the volume of water that an aquifer releases per unit area for a unit fall of head. For confined aquifers, S is small, often 0.0001 to 0.001, and for unconfined aquifers, it is close to the specific yield, 0.05 to 0.3.

When can I use the Cooper–Jacob approximation?

When u is small, below about 0.05, which happens at late times or short distances. Then W(u) is well approximated by −0.5772 − ln u, and the drawdown plots as a straight line against the log of time. Hydrogeologists use this feature to find T and S from a pumping test: the slope gives T and the intercept gives S.

Which assumptions does the Theis equation make?

The aquifer is confined, uniform in thickness and extent, infinite in area, with a constant T and S. The well is fully penetrating, pumped at a constant rate, and has a negligible radius. The water is released at once from storage when the head falls. Leaky layers, boundaries, partial penetration and wells that are not ideal call for other solutions.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.