Skip to content
Omnikalc

Waveplate thickness calculator: how thick is a quarter-wave or half-wave plate?

Choose the material, the plate type, the order and the wavelength to get the thickness of a quarter-wave or half-wave plate and its sensitivity to wavelength.

Updated on
Your inputs

Value out of range

Value out of range

nm

Value out of range

Results

Thickness of the plate

656.223 µm

Total retardation in waves
10.25
Birefringence used
0.0092
Wavelength shift for a 1/100 wave error
0.575 nm

A waveplate changes the polarization of light by delaying one component. The waveplate thickness calculator gives the thickness of a quarter-wave plate or a half-wave plate made of quartz, calcite, magnesium fluoride, sapphire or any material, from the order, the wavelength and the birefringence. It also shows the sensitivity of the plate to a change of wavelength.

How the calculation works

  • Choose the birefringent material (or enter a custom birefringence Δn = n_e − n_o), the type of plate and the order m.
  • A quarter-wave plate needs a retardation of (m + ¼) λ, and a half-wave plate (m + ½) λ.
  • The thickness is the retardation divided by the birefringence: d = (m + ¼ or ½) λ / Δn.
  • Order 0 gives the thinnest (zero-order) plate. A higher order is thicker and more robust, but more sensitive to wavelength and temperature.

Example

A quarter-wave plate of quartz (Δn = 0.0092) of order 10, for the sodium line at 589 nm, has a total retardation of 10.25 waves. Its thickness is 10.25 × 589 nm / 0.0092 = 656.2 µm. A shift of only 0.575 nm in wavelength changes the retardation by a hundredth of a wave.

Why it matters

Waveplates are everywhere in optics labs: they turn linear polarization into circular polarization, rotate the polarization of a laser, build optical isolators and control the light in polarimeters and in liquid crystal displays. The thickness needed is a few tens or hundreds of micrometers, so it must be computed with care.

Good to know

The calculator uses an average value of the birefringence for each material in the visible range, which varies by a few percent with the wavelength and with the temperature. Compound plates, made of two crystals with opposite axes, cancel most of this variation and are used in precision work. The thickness given is the optical design value, and the final plate is polished and tested to the tolerance of a fraction of a wave. Calcite has a negative birefringence, and the calculator uses its absolute value.

Malus’s law calculator gives the intensity through a polarizer, the refraction calculator covers the refractive index of the material, the wavelength calculator converts between wavelength and frequency, and the critical angle calculator covers total reflection in birefringent prisms.

Frequently asked questions

What is a waveplate?

A waveplate, or retarder, is a plate of birefringent material, in which the light polarized along the fast axis and the one polarized along the slow axis travel at different speeds. After the plate, one component is delayed with respect to the other by a fraction of a wavelength. This changes the state of polarization of the light.

What do the quarter-wave and half-wave plates do?

A quarter-wave plate, with a delay of ¼ λ, turns linearly polarized light at 45° to its axes into circularly polarized light, and the other way round. A half-wave plate, with a delay of ½ λ, rotates the plane of linear polarization by twice the angle between the polarization and the fast axis. It is used to rotate the polarization of a laser beam.

What is the difference between zero-order and multi-order plates?

A zero-order plate has the retardation of exactly ¼ or ½ wave, so it is very thin (a few tens of micrometers for quartz) and little sensitive to the wavelength and the temperature, but it is fragile. A multi-order plate adds m whole waves to the retardation, which makes it thicker and easier to handle, but the retardation varies m times faster with wavelength and temperature.

How does the wavelength change the retardation?

The plate is designed for a single wavelength. At another wavelength, the retardation in waves is d Δn / λ, which is different from the design value, and the plate is no longer exactly a quarter-wave or a half-wave plate. For a plate with a large total retardation N, a wavelength shift Δλ changes the retardation by about N Δλ / λ waves.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.