Skip to content
Omnikalc

Agitator power calculator: how much power a mixer impeller draws

Enter the impeller diameter and speed, the liquid density and viscosity, the impeller type and the volume of a stirred tank to get the Reynolds number, the power drawn, the power per volume and the tip speed.

Updated on
Your inputs
in

Value out of range

rpm

Value out of range

Value out of range

cP

Value out of range

gal

Value out of range

Results

Power drawn

0.275 hp

Reynolds number of the impeller
232,154
Fully turbulent: Np is constant
Power drawn by the impeller (turbulent flow)
151.5 ft·lbf/s
Power per 1,000 gallons
1.38 hp/1000 gal
Impeller tip speed
7.85 ft/s

The power drawn by an agitator depends on the power number of the impeller, the liquid density, the speed and the diameter. The agitator power calculator gives the Reynolds number, the power, the power per volume and the tip speed of a stirred tank.

How the calculation works

  • Enter the impeller diameter, the speed in rpm, the specific gravity and the viscosity of the liquid, and the volume in the tank.
  • Choose the impeller type, which sets the power number Np: about 5 for a Rushton turbine, 1.3 for a pitched-blade turbine and 0.3 for a hydrofoil or propeller.
  • The calculator computes the Reynolds number Re = ρ N D² / µ. If Re is above 10,000, the flow is turbulent and the power number is constant, so P = Np ρ N³ D⁵.
  • It gives the power in horsepower, the power per volume, a common design criterion (0.5 to 5 hp per 1,000 gal), and the tip speed.

Example

A 12 in Rushton turbine (Np = 5) turns at 150 rpm (2.5 rev/s) in 200 gal of water (SG = 1, 1 cP). The Reynolds number is 232,154, so the flow is turbulent. The power is P = 5 × 1.939 slug/ft³ × 2.5³ × 1⁵ = 151.5 ft·lbf/s = 0.275 hp, which is 1.38 hp per 1,000 gal. The tip speed is π × 1 × 2.5 = 7.85 ft/s.

Why it matters

The calculator helps process engineers, chemical plant and brewery technicians, water treatment operators and students to size the motor of a mixer, to compare impellers and speeds, and to scale a mixing process from a lab tank to a production tank. It avoids undersizing the drive.

Good to know

Use the viscosity at the working temperature and the real density of the mixture. Check that Re is above 10,000 before using a constant power number. Add a safety factor of 10% to 20% on the motor. Use baffles for a low-viscosity liquid, and check the shaft for the bending load and the critical speed.

The Reynolds number calculator explains the flow regimes, the pump power calculator sizes the pump motor, the motor current calculator checks the electrical supply and the tank volume calculator gives the volume of the tank.

Frequently asked questions

What is the power number of an impeller?

The power number Np = P / (ρ N³ D⁵) is the dimensionless power drawn by an impeller. It depends on the shape of the impeller and the tank, and it is constant in fully turbulent flow (Re above about 10,000). Typical values are 5 for a six-blade Rushton turbine, 1.3 for a four-blade pitched turbine at 45 degrees, and 0.3 for a hydrofoil. A high Np means a high power for the same speed and size.

How does the power change with the speed and size?

In turbulent flow, the power goes with the cube of the speed and the fifth power of the diameter. Doubling the speed multiplies the power by 8. Doubling the diameter at the same speed multiplies it by 32. This is why a small increase of speed or a larger impeller can overload a motor, and why a variable speed drive is useful for a mixer.

What is a good power per volume?

It depends on the duty. Gentle blending needs 0.1 to 0.5 hp per 1,000 gal, a typical mixing of miscible liquids 0.5 to 2, gas dispersion or liquid-liquid dispersion 2 to 10 or more, and suspension of heavy solids about 1 to 5. The power per volume is a scale-up criterion, but it does not by itself guarantee the mixing result, which also depends on the pumping flow of the impeller.

What are the limits of this calculator?

It applies to a baffled tank with a standard geometry, with the impeller diameter about one third of the tank diameter, and to a Newtonian liquid. In laminar flow (Re below about 10) the power is proportional to µ N² D³, not to ρ N³ D⁵. Without baffles, a vortex forms and the power falls. Gas sparging also reduces the power by 20% to 50%. Add 10% to 20% for the losses in the gearbox and seals.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.