The power drawn by an agitator depends on the power number of the impeller, the liquid density, the speed and the diameter. The agitator power calculator gives the Reynolds number, the power, the power per volume and the tip speed of a stirred tank.
How the calculation works
- Enter the impeller diameter, the speed in rpm, the specific gravity and the viscosity of the liquid, and the volume in the tank.
- Choose the impeller type, which sets the power number Np: about 5 for a Rushton turbine, 1.3 for a pitched-blade turbine and 0.3 for a hydrofoil or propeller.
- The calculator computes the Reynolds number Re = ρ N D² / µ. If Re is above 10,000, the flow is turbulent and the power number is constant, so P = Np ρ N³ D⁵.
- It gives the power in horsepower, the power per volume, a common design criterion (0.5 to 5 hp per 1,000 gal), and the tip speed.
Example
A 12 in Rushton turbine (Np = 5) turns at 150 rpm (2.5 rev/s) in 200 gal of water (SG = 1, 1 cP). The Reynolds number is 232,154, so the flow is turbulent. The power is P = 5 × 1.939 slug/ft³ × 2.5³ × 1⁵ = 151.5 ft·lbf/s = 0.275 hp, which is 1.38 hp per 1,000 gal. The tip speed is π × 1 × 2.5 = 7.85 ft/s.
Why it matters
The calculator helps process engineers, chemical plant and brewery technicians, water treatment operators and students to size the motor of a mixer, to compare impellers and speeds, and to scale a mixing process from a lab tank to a production tank. It avoids undersizing the drive.
Good to know
Use the viscosity at the working temperature and the real density of the mixture. Check that Re is above 10,000 before using a constant power number. Add a safety factor of 10% to 20% on the motor. Use baffles for a low-viscosity liquid, and check the shaft for the bending load and the critical speed.
Related tools
The Reynolds number calculator explains the flow regimes, the pump power calculator sizes the pump motor, the motor current calculator checks the electrical supply and the tank volume calculator gives the volume of the tank.