Blower door ACH50 calculator: air tightness of a building from a blower door test

Enter the blower door airflow at 50 Pa, the volume, the envelope area and the N-factor to get the air changes per hour at 50 Pa, the leakage per area and the estimated natural air change rate.

Updated on
Your inputs
cfm

Value out of range

ft³

Value out of range

ft²

Value out of range

Results

Air changes per hour at 50 Pa

2.50 ACH50

Meets the common code limit of 3 ACH50 (climate zones 3 to 8)
Natural air change rate (ACH50 divided by N)
0.147 ACH
Leakage per area of envelope at 50 Pa
0.20 cfm50 per ft²
Estimated natural infiltration airflow
58.8 cfm

The blower door ACH50 calculator converts the airflow of a blower door test at 50 Pa into the air changes per hour of the building, the leakage per area of envelope, an estimate of the natural air change rate with the N-factor and the natural infiltration airflow.

How the calculation works

  • Enter the airflow measured by the blower door at 50 Pa (CFM50), the conditioned volume and the envelope area.
  • Choose the N-factor from the exposure of the site and the number of stories.
  • The calculator gives the air changes per hour at 50 Pa: ACH50 = CFM50 × 60 / volume.
  • It also gives the leakage per envelope area, the estimated natural air change rate ACH50 / N and the natural infiltration airflow.

Example

A house of 24,000 ft³ with an envelope of 5,000 ft² leaks 1,000 cfm at 50 Pa. The ACH50 is 1,000 × 60 / 24,000 = 2.50, which meets the common limit of 3. With an N-factor of 17, the natural air change rate is 2.5 / 17 = 0.147 ACH, and the natural infiltration airflow is 1,000 / 17 = 58.8 cfm. The leakage per envelope area is 1,000 / 5,000 = 0.20 cfm50 per ft².

Why it matters

The calculator helps energy auditors, builders, architects, inspectors and homeowners to read the result of a blower door test, to compare it with code limits and with the targets of high-performance buildings and to estimate the heat lost by infiltration. It gives the numbers needed to decide on air sealing and on mechanical ventilation.

Good to know

Compare the result with the limit of your code and with the target of your project. Use the same volume as the test report, and note whether the test was done as a depressurization or a pressurization. The natural rate from the N-factor is only an estimate, so use a ventilation calculation to size the fresh air system. Do not seal a building with combustion appliances without checking the draft and the combustion air.

The air changes calculator covers ventilation rates, the heat loss calculator turns a leakage into a heating load, the wall U-value calculator covers the insulation of walls and the window area calculator checks glazing areas.

Frequently asked questions

What is ACH50?

ACH50 is the number of times per hour that the whole volume of air in a building is replaced when the building is depressurized or pressurized to 50 pascals with a blower door. It is the standard measure of air tightness in the United States. It is a test number and not the real air change rate under natural conditions, which is much smaller because the real pressures are only a few pascals.

What is a good ACH50 value?

The model energy codes require 5 ACH50 in climate zones 1 and 2, and 3 ACH50 in zones 3 to 8. Good new homes reach 1.5 to 3, high-performance homes about 1 or less, and the Passive House standard asks for 0.6. Older houses often have 8 to 15 ACH50. A tighter building needs mechanical ventilation to provide fresh air.

What is the N-factor?

The N-factor of the Lawrence Berkeley Laboratory converts the leakage at 50 Pa to an estimate of the average natural infiltration, ACH = ACH50 / N. It is about 10 to 30 and depends on the climate, the wind exposure and the number of stories. A tall exposed house has a lower N and so more natural infiltration for the same leakage. The result is only an order of magnitude.

How do I reduce the leakage?

Find the leaks with the blower door and a smoke pencil or a thermal camera, and seal the biggest ones first: the attic hatch and the penetrations of the top plate, the rim joists, the ducts, the recessed lights, the windows and doors, and the plumbing and electrical penetrations. Seal the leaks before adding insulation. After sealing, check the ventilation and the combustion appliances for safety.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.