Boiler size calculator: what size boiler does your house need?

Enter the floor area, the climate, the insulation, a hot water allowance and the AFUE to estimate the heat loss, the boiler output and input in BTU per hour and kilowatts.

Updated on
Your inputs
ft²

Value out of range

BTU/h

Value out of range

%

Value out of range

Results

Boiler net output needed (10 % pickup allowance)

81,400 BTU/h

Boiler input rating at the AFUE

95,765 BTU/h

Design heat loss of the house
70,000 BTU/h
Net output in kilowatts
23.9 kW
Next size up in steps of 10,000 BTU/h
90,000 BTU/h

A boiler that is too small leaves you cold on the coldest day and one that is too large wastes money all winter. This boiler size calculator takes the floor area, the climate, the insulation, an allowance for hot water and the efficiency to estimate the heat loss, the net output and the input rating in BTU per hour and kilowatts.

How the calculation works

  • Design heat loss = floor area × BTU/h per square foot for the climate × insulation factor (1.25 poor, 1.0 average, 0.8 good).
  • Net output needed = (heat loss + hot water allowance) × 1.1, a 10 % allowance for the morning pickup.
  • Input rating = net output ÷ AFUE, the fuel power the boiler must burn to deliver that heat.
  • Kilowatts = BTU/h ÷ 3,412.14, and the next size up is the net output rounded up to the next 10,000 BTU/h.

Example

A 2,000 ft² house in a moderate climate with average insulation has a heat loss of 2,000 × 35 × 1.0 = 70,000 BTU/h. With 4,000 BTU/h for an indirect tank and a 10 % pickup allowance, the boiler needs a net output of (70,000 + 4,000) × 1.1 = 81,400 BTU/h, or 23.9 kW. At 85 % AFUE the input rating is 95,765 BTU/h, and the next size up is a 90,000 BTU/h net boiler.

Why it matters

Boilers are often replaced with the same size as the old one, even though the house has since been insulated, and a bigger one is chosen to be on the safe side. A quick estimate shows whether the old size is right, and it provides a number to bring to a contractor, who should run a complete heat loss calculation before ordering.

Good to know

The rule-of-thumb figures per square foot are a rough guide, and a room-by-room heat loss calculation based on walls, windows, ceilings, air leaks and the design temperature of your location is the proper method. Insulation upgrades reduce the load and can allow a smaller boiler. Radiators, radiant floors and fan coils need different water temperatures, which affects the efficiency of a condensing boiler. Hot water demand, a swimming pool or a snow melt system adds load. Always have the final size confirmed by a licensed installer.

The furnace replacement cost calculator estimates the cost of a new unit, the heat loss calculator finds the load room by room and the heating degree days calculator measures how cold a season is.

Frequently asked questions

How do I size a boiler?

Find the heat loss of the house on the coldest design day, add an allowance for hot water if the boiler heats a tank, and choose a boiler with a net output slightly above that. A proper sizing uses a room-by-room heat loss calculation (Manual J).

What is AFUE?

Annual fuel utilization efficiency is the share of the fuel energy that becomes heat in the house over a season. A standard boiler is about 80 to 85 % and a condensing boiler reaches 90 to 98 %.

Is a bigger boiler better?

No. An oversized boiler turns on and off too often, wastes fuel, wears faster and heats unevenly. Condensing boilers also condense less when they cycle, which lowers their efficiency.

What is the difference between net and gross output?

Gross or input rating is the fuel energy burned. Net or DOE heating capacity is the heat delivered to the water. Size to the net output and compare prices on that basis.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.