Broad-crested weir calculator: flow over a weir with a wide flat crest

Enter the crest width, the head over the crest, the crest length and the discharge coefficient to get the flow over a broad-crested weir, the critical depth, the velocity and a check of the validity range.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

ft

Value out of range

Value out of range

Results

Discharge

48.21 cfs

Discharge in gallons per minute
21,640 gpm
Discharge per unit width
4.821 cfs/ft
Critical depth on the crest
1.000 ft
Velocity on the crest
5.672 ft/s
Head to crest length ratio H/L
0.250
H/L between 0.08 and 0.5: a true broad-crested weir

A weir with a wide flat crest is one of the simplest ways to measure or to control the flow of a channel. The broad-crested weir calculator gives the discharge from the head, the crest width and the discharge coefficient, with the critical depth, the velocity and a check that the H/L ratio is in the valid range.

How the calculation works

  • Enter the width b of the crest, the head H over the crest, measured upstream of the weir, and the length L of the crest in the flow direction.
  • Enter the discharge coefficient Cd, between 0.85 and 1.0 for a well-built weir with a rounded upstream edge.
  • The calculator applies Q = Cd × (2/3) × √(2g/3) × b × H^1.5, which comes from a critical flow on the crest.
  • It also gives the critical depth (2/3 of the head), the velocity on the crest and a check of the ratio H/L, which must be between 0.08 and 0.5.

Example

A weir crest has a width of 10 ft, a length of 6 ft and a head of 1.5 ft, with a coefficient of 0.85. The discharge is 0.85 × 3.0876 × 10 × 1.5^1.5 = 48.21 cfs, or 21,640 gpm. The critical depth on the crest is 1.000 ft, the velocity 5.672 ft/s, and H/L is 0.250, within the valid range.

Why it matters

The calculator helps engineers, irrigation managers, farmers and students to size a weir or a check structure, to estimate the flow in a canal from a measured head and to design a culvert inlet or a spillway crest.

Good to know

The formula is for free flow over a rectangular crest in a level channel, with a head measured at a distance of 2 to 4 times H upstream of the weir. It ignores the velocity of approach, which matters when the weir is not much higher than the channel, and the effects of sediment, vegetation and a crest that is not level. For legal or billing measurements, use the calibration and the tolerance of the standard.

The weir flow calculator covers sharp-crested weirs, the hydraulic jump calculator gives the depths downstream, the orifice flow calculator covers openings under a head, and the peak flow calculator estimates the flood flow of a watershed.

Frequently asked questions

What is a broad-crested weir?

It is a flat-topped obstruction in an open channel, long enough in the flow direction for the streamlines to be parallel on the crest, which happens when the head is between 8 % and 50 % of the crest length. The flow passes through critical depth on the crest, so the discharge depends only on the head upstream and not on the downstream level, as long as the weir is not submerged. Broad-crested weirs are strong and common in irrigation canals, culverts and spillways.

What is the formula?

From the energy equation, the critical depth on the crest is 2/3 of the head, and the critical velocity is √(g × 2H/3). The discharge per unit width is therefore q = Cd × (2/3)^1.5 × √g × H^1.5, which is Q = 1.705 Cd b H^1.5 in SI units (m³/s, m) and Q = 3.087 Cd b H^1.5 in US units (cfs, ft). The coefficient Cd accounts for the friction and for the shape of the upstream edge.

What value of Cd should I use?

A value of 0.85 is common for a rectangular crest with a sharp upstream corner, because of the contraction of the flow. With a well-rounded upstream edge the coefficient goes to 0.95 to 1.0. The value also depends on the ratio H/L and on the roughness of the crest. For work that needs accuracy, calibrate the weir in place, or use a standard such as ISO 3846 for rectangular broad-crested weirs.

When is the weir drowned?

When the downstream water level rises over about 80 % of the head above the crest, the flow is submerged and the simple formula overestimates the flow. The discharge then depends on the downstream level and a correction factor is needed. The calculator is for free flow, with the water falling freely or in a supercritical flow downstream of the crest.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.