Skip to content
Omnikalc

How much water flows over your weir?

Enter the head over the crest, the crest width and the type of weir: get the flow rate in m³/s, litres per second, cubic feet per second and gallons per minute.

Updated on
Your inputs

Value out of range

Value out of range

Results

Flow rate

0.1037 m³/s

Within the usual range of the formula

Flow rate in litres per second

103.7 L/s

Flow rate in cubic feet per second
3.66 cfs
Flow rate in US gallons per minute
1,643 gpm
Volume per hour
373.3 m³/h

A weir is a plate or a low wall across a channel, with water spilling over its crest. Because the flow grows in a predictable way with the depth of the water above the crest, a weir doubles as a simple flow meter. This calculator uses the Francis formula for a sharp-crested rectangular weir and the standard formula for a 90° V-notch, and gives the flow in several units.

How the calculation works

  • Rectangular weir: Q = 1.84 × (L − 0.1 × n × H) × H^1.5
  • 90° V-notch weir: Q = 1.38 × H^2.5
  • Q in m³/s, with the crest width L and the head H in metres
  • n is the number of end contractions: 0, 1 or 2

Example

A rectangular weir 1 m wide, with contractions at both ends, has a head of 0.15 m. The effective width is 1 − 0.1 × 2 × 0.15 = 0.97 m. The flow is 1.84 × 0.97 × 0.15^1.5 = 0.1037 m³/s, which is 103.7 L/s, 3.66 cfs or 1,643 gpm, about 373 m³ per hour.

Where it is used

Weirs measure the flow of streams, irrigation ditches, wastewater plants, drains and industrial discharges. A V-notch is common for small streams, because a small flow still produces a measurable depth. Environmental agencies, farmers and water engineers use them to monitor flows, to size ponds and to check pump output.

Good to know

The formulas assume a sharp-crested weir with a thin edge, a free fall of water below the crest with air under the jet, and an approach channel that is wide and deep enough for a calm flow. The head must be measured correctly, upstream of the drawdown. Sediment build-up, weeds and a submerged downstream level all change the result. Clean the weir plate regularly and keep a fixed gauge or ruler next to it so that readings from different days can be compared. For official measurements, standards such as ISO 1438 define the dimensions.

For open channels, use the Manning equation calculator. For flow in a pipe, the pipe flow velocity calculator, and for tank draining, the tank drain time calculator.

Frequently asked questions

What is a weir?

A low dam or a plate with a notch across a channel. The depth of the water above its crest, called the head, tells you the flow, which makes it a simple and cheap flow meter for streams, ditches and drains.

How does a V-notch differ from a rectangular weir?

A V-notch gives a more accurate reading at small flows, because the width of the stream rises with the head. A rectangular weir is better for larger flows.

What is the Francis formula?

Q = 1.84 × (L − 0.1 × n × H) × H^1.5, with the flow in cubic metres per second and the lengths in metres. The term with n corrects for the end contractions of the stream.

Where do I measure the head?

In still water upstream, at least four times the maximum head from the weir plate, not at the crest itself, where the water surface drops.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.