A weir is a plate or a low wall across a channel, with water spilling over its crest. Because the flow grows in a predictable way with the depth of the water above the crest, a weir doubles as a simple flow meter. This calculator uses the Francis formula for a sharp-crested rectangular weir and the standard formula for a 90° V-notch, and gives the flow in several units.
How the calculation works
- Rectangular weir: Q = 1.84 × (L − 0.1 × n × H) × H^1.5
- 90° V-notch weir: Q = 1.38 × H^2.5
- Q in m³/s, with the crest width L and the head H in metres
- n is the number of end contractions: 0, 1 or 2
Example
A rectangular weir 1 m wide, with contractions at both ends, has a head of 0.15 m. The effective width is 1 − 0.1 × 2 × 0.15 = 0.97 m. The flow is 1.84 × 0.97 × 0.15^1.5 = 0.1037 m³/s, which is 103.7 L/s, 3.66 cfs or 1,643 gpm, about 373 m³ per hour.
Where it is used
Weirs measure the flow of streams, irrigation ditches, wastewater plants, drains and industrial discharges. A V-notch is common for small streams, because a small flow still produces a measurable depth. Environmental agencies, farmers and water engineers use them to monitor flows, to size ponds and to check pump output.
Good to know
The formulas assume a sharp-crested weir with a thin edge, a free fall of water below the crest with air under the jet, and an approach channel that is wide and deep enough for a calm flow. The head must be measured correctly, upstream of the drawdown. Sediment build-up, weeds and a submerged downstream level all change the result. Clean the weir plate regularly and keep a fixed gauge or ruler next to it so that readings from different days can be compared. For official measurements, standards such as ISO 1438 define the dimensions.
Related tools
For open channels, use the Manning equation calculator. For flow in a pipe, the pipe flow velocity calculator, and for tank draining, the tank drain time calculator.