How deep is the water after a hydraulic jump?

Enter the flow rate, the channel width and the depth before the jump: get the depth after the jump, the Froude number, the energy lost and the jump length.

Updated on
Your inputs

Value out of range

Value out of range

Value out of range

Results

Depth after the jump

1.018 m

Weak jump: smooth surface, energy loss under 20%
Depth after the jump in feet
3.34 ft
Froude number before the jump
2.14
Velocity before the jump
4.22 m/s
Velocity after the jump
1.64 m/s
Head (energy) lost in the jump
0.149 m
Share of the upstream energy lost
11.4%
Power dissipated
7.4 kW
Approximate jump length
6.1 m

A hydraulic jump is the abrupt rise in water level you see at the foot of a dam spillway, below a sluice gate or in a kitchen sink where the stream spreads out. It happens when fast, shallow flow suddenly slows down and gets deeper. This calculator takes the flow rate, the channel width and the depth before the jump and gives the depth after the jump, the Froude number, the energy lost and the approximate length of the jump.

How the calculation works

  • Velocity before the jump: v₁ = Q ÷ (b × y₁)
  • Froude number: Fr₁ = v₁ ÷ √(g × y₁)
  • Depth after the jump: y₂ = (y₁ ÷ 2) × (√(1 + 8 × Fr₁²) − 1)
  • Head lost: ΔE = (y₂ − y₁)³ ÷ (4 × y₁ × y₂)
  • Power dissipated: P = ρ × g × Q × ΔE
  • Jump length: about 6 × y₂ for a horizontal channel

Example

A flow of 180 ft³/s (5.1 m³/s) in a channel 10 ft wide arrives at a depth of 1.3 ft. The velocity is 4.22 m/s and the Froude number is 2.14, so the jump is weak. The depth after the jump is 1.018 m (3.34 ft), the head lost is 0.149 m, about 11% of the upstream energy, and the power dissipated is 7.4 kW. The jump is roughly 6.1 m (20 ft) long.

Why it matters

Fast water leaving a spillway can scour the riverbed and undermine the structure. Engineers force a jump inside a stilling basin so that the energy is dissipated in turbulence instead of erosion. The depth after the jump sets the height of the basin walls, and the length sets the length of the concrete apron.

Good to know

Jump strength depends on the Froude number. Below 1.7 the jump is undular, from 1.7 to 2.5 weak, from 2.5 to 4.5 oscillating, from 4.5 to 9 steady and above 9 strong. Steady jumps dissipate energy best. The result is an estimate for a horizontal, smooth rectangular channel; a design for a real structure must be checked by a hydraulic engineer.

The Manning equation calculator gives the normal depth of flow in a channel, the weir flow calculator gives the discharge over a weir, and the Reynolds number calculator tells you whether the flow is turbulent.

Frequently asked questions

What is a hydraulic jump?

A sudden rise in water depth that occurs when fast, shallow (supercritical) flow slows down to slow, deep (subcritical) flow. Part of the flow energy is turned into turbulence and heat, which is why jumps are used below spillways and gates.

What does the Froude number tell me?

It compares the flow velocity with the speed of a surface wave. Above 1 the flow is supercritical and a jump can form. The higher the Froude number, the stronger the jump and the greater the share of energy lost.

How is the depth after the jump found?

With the Bélanger equation: y₂ = (y₁ ÷ 2) × (√(1 + 8 × Fr₁²) − 1), which comes from balancing momentum across the jump in a rectangular channel.

Does this work for any channel shape?

No. The formulas are for a horizontal rectangular channel with a smooth bed. Trapezoidal and circular channels need other relations, and a sloping bed lengthens the jump.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.