Skip to content
Omnikalc

Cake filtration calculator: how long a filter takes to collect a filtrate volume

Enter the filtrate volume, the filter area, the pressure drop, the viscosity and the cake and medium resistances to get the filtration time at constant pressure, the share of the cake resistance, the average flux and the cake mass.

Updated on
Your inputs
gal

Value out of range

ft²

Value out of range

psi

Value out of range

cP

Value out of range

Value out of range

lb/ft³

Value out of range

Value out of range

Results

Filtration time

30.9 min

Share of the resistance due to the cake
86.7 %
The cake dominates: a thinner cake or a filter aid helps
Average filtration flux
0.809 gal/min·ft²
Mass of dry cake
133.7 lb

In cake filtration, the solids build a cake that slows the filtrate. The cake filtration calculator applies Ruth’s equation at constant pressure to give the filtration time, the share of the resistance of the cake, the average flux and the mass of cake for a filter.

How the calculation works

  • Enter the volume of filtrate to collect, the filter area, the pressure drop (constant during the run) and the viscosity of the filtrate.
  • Enter the specific cake resistance α (10⁹ to 10¹² m/kg, in units of 10¹⁰ m/kg here), the mass of solids deposited per volume of filtrate and the resistance of the filter medium Rm.
  • The calculator applies Ruth’s equation for a constant-pressure filtration: t = µ α c V² / (2 A² ΔP) + µ Rm V / (A ΔP), where the first term is the cake and the second is the medium.
  • It gives the time to collect the filtrate, the share of the resistance due to the cake, the average flux and the mass of cake.

Example

A filter of 20 ft² (1.858 m²) works at 30 psi with a filtrate of 1 cP. The slurry deposits 2 lb of solids per ft³ of filtrate (32.0 kg/m³), the cake resistance is α = 2×10¹⁰ m/kg and the medium resistance is 5×10¹⁰ 1/m. To collect 500 gal (1.893 m³), the cake term is 1,607 s and the medium term is 246 s, so the filtration time is 1,853 s = 30.9 min. The cake makes 86.7% of the resistance, the average flux is 0.809 gal/min·ft² and the cake mass is 133.7 lb.

Why it matters

The calculator helps chemical, pharmaceutical, mining and water treatment engineers, filter press operators and students to size a filter, to estimate the cycle time, and to see the effect of the pressure, the area and the cake resistance. It supports the decision to add a filter aid or a larger area.

Good to know

Measure α on the real slurry, at the pressure of the process. Check whether the cake is compressible. Include the time for the cake washing, the discharge and the cleaning of the cycle. Raise the area before the pressure when the cake is compressible, because the pressure then gives little gain.

The Ergun equation calculator covers flow through a packed bed, Darcy’s law calculator gives the flow through a porous medium, the pump power calculator sizes the feed pump and the Stokes’ law calculator gives the settling of the solids.

Frequently asked questions

What is cake filtration?

In cake filtration, a slurry is forced through a filter medium such as a cloth or a screen. The solids are retained on the medium and build up a cake, and the clear liquid, the filtrate, passes through the cake and the medium. As the cake grows, its resistance rises and the flow falls at a constant pressure. It is the basis of filter presses, vacuum drum filters, Nutsche filters and leaf filters.

What is Ruth’s equation?

For a constant pressure drop, Ruth’s equation gives the time t to collect a volume V of filtrate: t = (µ α c / (2 A² ΔP)) V² + (µ Rm / (A ΔP)) V. The first term is the resistance of the cake, which grows with V², the second is that of the medium, which grows with V. The time grows faster than the volume, so a double filtrate volume takes more than twice the time.

How are α and Rm found?

They are measured in the lab by a filtration test with the slurry. The filtrate volume is recorded against time at a constant pressure, and the plot of t / V against V is a straight line, with the slope µ α c / (2 A² ΔP) and the intercept µ Rm / (A ΔP). Typical specific resistances go from 10⁹ m/kg for a coarse crystalline solid to 10¹² m/kg or more for a compressible, fine or biological slurry.

What are the limits of this calculator?

The equation assumes an incompressible cake, which has a constant α. Real cakes, such as those of clays and hydroxides, are compressible, and α rises with the pressure. The equation also assumes a constant pressure, a uniform cake, a negligible settling of the solids and no washing or dewatering step. For a scale-up, run a bench test and use its measured α.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.