Skip to content
Omnikalc

Critical insulation radius calculator: the size below which insulation adds heat loss

Enter the shape, the radius of the bare object, the insulation conductivity and the outside heat transfer coefficient to find the critical radius of insulation.

Updated on
Your inputs
in

Value out of range

BTU·in/h·ft²·°F

Value out of range

BTU/h·ft²·°F

Value out of range

Results

Critical insulation radius

0.670 in

Insulation thickness to reach it
0.610 in
Heat loss at the critical radius ÷ bare heat loss
3.27 ×
Adding insulation up to the critical radius increases the heat loss

Adding insulation does not always reduce heat loss. For a small pipe, wire or sphere, a thin layer can make it worse. This critical insulation radius calculator finds the critical radius from the shape, the bare radius, the conductivity of the insulation and the outside heat transfer coefficient, and gives the thickness needed and the heat loss at the critical radius compared with the bare object.

How the calculation works

  • Choose the shape (a cylinder such as a pipe or a wire, or a sphere) and enter the outer radius of the bare object, the conductivity of the insulation and the outside heat transfer coefficient.
  • The critical radius is r = k / h for a cylinder and r = 2k / h for a sphere.
  • Below this radius, a thin layer of insulation increases the heat loss, because the outer area grows faster than the resistance of the layer.
  • The calculator also gives the thickness needed to reach the critical radius and the heat loss at that radius compared with the bare object.

Example

A bare wire of 0.06 in radius is covered with an insulation of k = 1.18 BTU·in/h·ft²·°F in air with h = 1.76 BTU/h·ft²·°F. The critical radius of the cylinder is k / h = 0.670 in, so the insulation must be 0.610 in thick before it begins to help. At that radius, the heat loss is 3.3 times that of the bare wire.

Why it matters

The critical radius explains a surprising effect, and it helps when designing the insulation of small tubes, refrigerant lines, electric wires and heating elements. If the bare radius is below the critical radius, the insulation must be thick enough to pass it, or else it should be left out, or a better insulator with lower conductivity must be used.

Good to know

The calculator is for steady conduction through a uniform insulation layer and for a constant outside coefficient h, which includes convection and radiation. It ignores the contact resistance, the change of conductivity with temperature, the resistance of the pipe wall and of the fluid inside, and the effect of the diameter on h, which becomes lower for a larger outside diameter. For a pipe, the loss per unit length is the quantity considered.

The heat conduction calculator covers the flow through a layer, the wall U-value calculator covers building walls, the insulation calculator sizes a layer for a building, and the heat loss calculator estimates the total loss.

Frequently asked questions

What is the critical insulation radius?

It is the outer radius of the insulation for which the total heat loss of a cylinder or sphere is largest. Adding insulation has two effects: it adds a conduction resistance, and it enlarges the outer surface, which lowers the resistance of convection to the air. For a small object, the second effect wins at first, so a thin layer increases the loss.

Does it matter for a building pipe?

Usually not. The critical radius of a cylinder is k / h, which is about 0.5 to 1 in (12 to 25 mm) for common insulation in still air. Water pipes and ducts in a building have a radius larger than that, so every layer of insulation reduces the heat loss. It matters for thin wires, small tubes and electric cables.

Why is it useful for electric wires?

A wire carrying a current is heated by the current, and its coating of plastic may act as a heat sink if the outer radius is below the critical value. Within that range, a thicker coating makes the wire cooler, which allows a higher current. The effect is the base of the thermal rating of cables.

What changes the critical radius?

A better insulation (lower k) gives a smaller critical radius, and a higher outside coefficient h (wind or forced air) also gives a smaller one. Radiation adds to the coefficient, so it also reduces the critical radius. A sphere has a critical radius twice that of a cylinder for the same k and h.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.