The eccentric bolt group calculator gives the force on the critical bolt of a vertical line of bolts loaded with an eccentric load, with the elastic method: the moment, the direct shear, the moment force and the resultant, compared with the bolt capacity.
How the calculation works
- Enter the vertical load, its eccentricity from the line of bolts, the number of bolts and the spacing.
- Enter the shear capacity of one bolt, from the specification or the bolt table.
- The calculator finds the moment M = P e and the sum of y² of the bolts, Σy² = s² n (n² − 1) / 12.
- It gives the direct shear P / n, the horizontal force from the moment at the outer bolt, the resultant and the ratio to the capacity.
Example
A bracket carries 20 kips at an eccentricity of 4 in on a line of 4 bolts at 3 in spacing. The moment is 20 × 4 = 80 kip-in. Σy² = 9 × 4 × 15 / 12 = 45 in², and the outer bolt is at 4.5 in. The horizontal force is 80 × 4.5 / 45 = 8.00 kips, and the direct shear is 20 / 4 = 5.00 kips. The resultant is √(8² + 5²) = 9.43 kips, which is 0.63 of a bolt capacity of 15 kips.
Why it matters
The calculator helps structural engineers, detailers, fabricators and students to check a bracket, a shear tab or a seat connection, to find the number of bolts needed for an eccentric load and to see the effect of the spacing. It reproduces the standard hand calculation.
Good to know
Use the capacity of the bolt in shear, with the correct number of shear planes and thread conditions, and check the bearing on the plates too. Measure the eccentricity from the centroid of the bolt line to the line of action of the load. For two or more lines of bolts, or for loads that are not perpendicular, use the full group method of the AISC manual or a software.
Related tools
The bolt shear capacity calculator gives the capacity of a bolt, the bolt torque calculator covers tightening, the Whitmore gusset width calculator covers gusset plates and the fillet weld strength calculator covers welded connections.