Skip to content
Omnikalc

Eccentric bolt group calculator: force on the critical bolt of a bracket connection

Enter the load, the eccentricity, the number and spacing of the bolts and the bolt capacity to get the moment, the direct and the moment forces and the resultant force on the critical bolt.

Updated on
Your inputs
kips

Value out of range

in

Value out of range

Value out of range

in

Value out of range

kips

Value out of range

Results

Resultant force on the critical bolt

9.43 kips

Moment on the bolt group
80.0 kip-in
Direct shear per bolt (load divided by the number of bolts)
5.00 kips
Horizontal force on the outer bolt from the moment
8.00 kips
Critical bolt force over bolt capacity
0.63
The most loaded bolt is within its capacity

The eccentric bolt group calculator gives the force on the critical bolt of a vertical line of bolts loaded with an eccentric load, with the elastic method: the moment, the direct shear, the moment force and the resultant, compared with the bolt capacity.

How the calculation works

  • Enter the vertical load, its eccentricity from the line of bolts, the number of bolts and the spacing.
  • Enter the shear capacity of one bolt, from the specification or the bolt table.
  • The calculator finds the moment M = P e and the sum of y² of the bolts, Σy² = s² n (n² − 1) / 12.
  • It gives the direct shear P / n, the horizontal force from the moment at the outer bolt, the resultant and the ratio to the capacity.

Example

A bracket carries 20 kips at an eccentricity of 4 in on a line of 4 bolts at 3 in spacing. The moment is 20 × 4 = 80 kip-in. Σy² = 9 × 4 × 15 / 12 = 45 in², and the outer bolt is at 4.5 in. The horizontal force is 80 × 4.5 / 45 = 8.00 kips, and the direct shear is 20 / 4 = 5.00 kips. The resultant is √(8² + 5²) = 9.43 kips, which is 0.63 of a bolt capacity of 15 kips.

Why it matters

The calculator helps structural engineers, detailers, fabricators and students to check a bracket, a shear tab or a seat connection, to find the number of bolts needed for an eccentric load and to see the effect of the spacing. It reproduces the standard hand calculation.

Good to know

Use the capacity of the bolt in shear, with the correct number of shear planes and thread conditions, and check the bearing on the plates too. Measure the eccentricity from the centroid of the bolt line to the line of action of the load. For two or more lines of bolts, or for loads that are not perpendicular, use the full group method of the AISC manual or a software.

The bolt shear capacity calculator gives the capacity of a bolt, the bolt torque calculator covers tightening, the Whitmore gusset width calculator covers gusset plates and the fillet weld strength calculator covers welded connections.

Frequently asked questions

What is an eccentric connection?

A connection is eccentric when the line of action of the load does not pass through the centroid of the bolt group. The load then produces a shear on the bolts, and also a moment that twists the group about its centroid. A typical example is a bracket or a beam end plate attached to a column with a vertical line of bolts, with the load applied at a distance from the line of bolts.

How does the elastic method work?

The elastic method assumes that the connected plate is rigid and the bolts are elastic. The direct shear is shared equally among the bolts, P / n. The moment M = P e makes each bolt carry a force proportional to its distance from the centroid, so the force on the bolt at the distance y is M y / Σy², in the direction perpendicular to the radius. The two forces are added as vectors at each bolt.

Which bolt is critical?

For a vertical line of bolts with a vertical load, the moment forces are horizontal and the direct shear is vertical, so they add at right angles. The bolts farthest from the centroid have the largest moment force and therefore the largest resultant, which is the critical bolt. For a group with several lines of bolts, the resultant must be computed with both components for each bolt.

What are the limits of the method?

The elastic method is conservative compared with the instantaneous center of rotation method of the AISC manual, which accounts for the ductility of the bolts and gives a higher capacity of 10 to 30%. The calculator is for one line of bolts. It does not check the bearing and the tearout of the plate, the plate bending or the weld, which are also needed. The design of a real connection must be verified by an engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.