The strength of a bolted connection is the smaller of the bolt shear and the plate bearing. The bolt shear capacity calculator gives the design strength per bolt of A325 and A490 bolts in the LRFD method, the governing limit state and the strength of the whole group.
How the calculation works
- Choose the bolt diameter, the grade (A325 or A490) and whether the threads are in the shear plane (N) or excluded from it (X).
- Enter the number of shear planes (1 for a lap joint, 2 for a double shear joint) and the number of bolts.
- Enter the thickness and tensile strength of the connected plate, and the clear distance from the edge of the hole to the edge of the plate.
- The calculator gives the design shear strength and the design bearing strength of each bolt, the governing value and the strength of the group.
Example
Four 3/4 in A325-N bolts in single shear connect a 3/8 in plate with Fu = 58 ksi, with a clear distance of 1.25 in. The bolt area is 0.442 in², so the design shear strength is 0.75 × 54 × 0.442 = 17.89 kips per bolt. The bearing strength is 0.75 × 1.2 × 1.25 × 0.375 × 58 = 24.47 kips. The shear controls with 17.89 kips per bolt and the group has 71.6 kips.
Why it matters
The calculator helps structural engineering students, steel detailers and engineers to check a simple connection quickly, to see whether the bolts or the plate govern and to compare bolt sizes and grades. It is a time saver for hand calculations and for checking the result of a design program.
Good to know
The calculator applies the basic AISC LRFD equations for bolts in shear in bearing-type connections with standard holes, and for the bearing strength of the plate when the deformation is considered. It does not check the minimum spacing, the block shear, the combined tension, the slip-critical joints, the oversize or slotted holes or the strength of the member. Treat the result as a check and not as a design.
Related tools
The bolt torque calculator gives the tightening torque, the section modulus calculator gives the bending capacity of a member, the Euler buckling calculator checks a slender column, and the punching shear calculator checks a slab around a column.