Skip to content
Omnikalc

Bolt shear and bearing capacity calculator: A325 and A490 bolts, LRFD design strength

Choose the bolt size and grade and enter the plate thickness, strength and edge distance to get the design shear and bearing strength per bolt, the governing limit state and the strength of the group.

Updated on
Your inputs

Value out of range

Value out of range

in

Value out of range

ksi

Value out of range

in

Value out of range

Results

Design strength of the bolt group

71.6 kips

Design shear strength per bolt (φRn)
17.89 kips
Design bearing strength per bolt (φRn)
24.47 kips
Governing strength per bolt
17.89 kips
Governing limit state (1 = bolt shear, 2 = plate bearing)
1
The bolt shear controls: use more or larger bolts, or threads excluded

The strength of a bolted connection is the smaller of the bolt shear and the plate bearing. The bolt shear capacity calculator gives the design strength per bolt of A325 and A490 bolts in the LRFD method, the governing limit state and the strength of the whole group.

How the calculation works

  • Choose the bolt diameter, the grade (A325 or A490) and whether the threads are in the shear plane (N) or excluded from it (X).
  • Enter the number of shear planes (1 for a lap joint, 2 for a double shear joint) and the number of bolts.
  • Enter the thickness and tensile strength of the connected plate, and the clear distance from the edge of the hole to the edge of the plate.
  • The calculator gives the design shear strength and the design bearing strength of each bolt, the governing value and the strength of the group.

Example

Four 3/4 in A325-N bolts in single shear connect a 3/8 in plate with Fu = 58 ksi, with a clear distance of 1.25 in. The bolt area is 0.442 in², so the design shear strength is 0.75 × 54 × 0.442 = 17.89 kips per bolt. The bearing strength is 0.75 × 1.2 × 1.25 × 0.375 × 58 = 24.47 kips. The shear controls with 17.89 kips per bolt and the group has 71.6 kips.

Why it matters

The calculator helps structural engineering students, steel detailers and engineers to check a simple connection quickly, to see whether the bolts or the plate govern and to compare bolt sizes and grades. It is a time saver for hand calculations and for checking the result of a design program.

Good to know

The calculator applies the basic AISC LRFD equations for bolts in shear in bearing-type connections with standard holes, and for the bearing strength of the plate when the deformation is considered. It does not check the minimum spacing, the block shear, the combined tension, the slip-critical joints, the oversize or slotted holes or the strength of the member. Treat the result as a check and not as a design.

The bolt torque calculator gives the tightening torque, the section modulus calculator gives the bending capacity of a member, the Euler buckling calculator checks a slender column, and the punching shear calculator checks a slab around a column.

Frequently asked questions

How is the shear strength of a bolt computed?

In the AISC specification, the nominal shear strength of a bolt is Rn = Fnv × Ab × the number of shear planes, where Fnv is the nominal shear stress and Ab is the nominal area of the bolt. The values of Fnv are 54 ksi for A325 bolts with the threads in the shear plane, 68 ksi for A325 with threads excluded or A490 with threads in, and 84 ksi for A490 with threads excluded. The design strength for LRFD is φRn with φ = 0.75.

What is bearing strength?

The bearing strength is the capacity of the plate around the bolt hole to resist the force of the bolt without tearing out or crushing. For a standard hole with deformation considered, Rn = 1.2 Lc t Fu, limited to 2.4 d t Fu, where Lc is the clear distance in the direction of the force, t is the plate thickness, Fu is the tensile strength and d is the bolt diameter. A short edge distance reduces the bearing strength.

What is the difference between N and X bolts?

In an N connection the threads of the bolt are in the shear plane, and in an X connection they are excluded from it. The threaded part has a smaller area, so the shear strength is lower for the N condition. The X condition needs that the shear plane falls in the shank, which depends on the grip. The designation must be shown on the drawings.

Does the calculator cover tension or slip-critical joints?

No. It covers bolts in shear and bearing only, in the bearing-type connection. It does not check the combined tension and shear, the slip resistance of the slip-critical joints, the block shear of the plate, the strength of the plate itself or the minimum spacing and edge distances. Use the AISC specification and a structural engineer for the real design.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.