Fillet weld strength calculator: how much load can your welds carry?

Enter the electrode, the leg size and the weld length to get the effective throat, the AISC design strength and the load ratio of a fillet weld.

Updated on
Your inputs
in

Value out of range

in

Value out of range

Value out of range

kip

Value out of range

Results

Load ratio Pu / φRn

0.82

The welds carry the load
Effective throat of the weld
0.177 in
Design strength per inch of weld
5.57 kip/in
Total design strength φRn
66.8 kip
Minimum length of each weld (4 × leg)
1.00 in

A fillet weld holds two pieces of steel together by a triangle of weld metal, and its strength depends on the thickness of that triangle at its weakest plane. The fillet weld strength calculator takes the electrode strength, the leg size, the length of each weld, the number of welds and the factored load, and gives the effective throat, the design strength per inch, the total design strength, the load ratio and the minimum weld length.

How the calculation works

  • Pick the electrode strength (FEXX), then enter the leg size of the fillet weld, the length of each weld and the number of welds that share the load.
  • Enter the factored load Pu that the welds must carry in shear.
  • The effective throat is 0.707 × leg. The AISC nominal strength per unit length is Rn = 0.60 × FEXX × throat, and the design strength applies φ = 0.75.
  • Compare the design strength with the load. A ratio of 1.0 or less means the weld metal is strong enough, and the minimum length of 4 × leg is a detailing rule.

Example

Two 1/4 in fillet welds of E70 electrodes, each 6 in long, carry a load of 55 kip. The throat is 0.707 × 0.25 = 0.177 in. The nominal strength is 0.6 × 70 × 0.177 = 7.42 kip/in, and the design strength is 0.75 × 7.42 = 5.57 kip/in. The two welds give 5.57 × 6 × 2 = 66.8 kip, so the ratio is 55 / 66.8 = 0.82, which passes.

Why it matters

Welded connections are among the most common details in steel work, and the size of the weld decides the cost in labour and filler metal. A quick check shows whether a weld size is enough, how much you gain from a longer weld than from a larger one, and when the base metal is more likely to govern.

Good to know

The calculator covers the weld metal strength in shear according to the AISC 360 LRFD method. It does not check the base metal, the block shear, the minimum and maximum leg sizes for the plate thickness, the fatigue or the eccentricity of the load. Welds must be made by qualified welders under an approved procedure. Treat the result as a screening check.

The welding heat input calculator gives the energy of a weld pass, the carbon equivalent calculator rates the weldability of the steel, the bolt torque calculator sizes bolted alternatives, and the metal weight calculator estimates the mass of plate and bar.

Frequently asked questions

What is the throat of a fillet weld?

It is the shortest distance from the root of the weld to its face, the dimension that is sheared when the weld fails. For an equal-leg fillet weld with a flat face, it equals 0.707 times the leg. The strength of the weld depends on the throat and not on the leg, so a 1/4 in weld has a throat of only 0.177 in.

What does FEXX mean?

FEXX is the minimum tensile strength of the weld metal, given by the electrode classification. In E70XX, the 70 stands for 70 ksi. The design shear strength of a fillet weld is 60 % of that value, times the factor φ = 0.75 in the AISC LRFD method. The base metal must also be checked, since it may govern.

Why is there a minimum length?

A weld that is too short for its leg size has an end effect that makes the leg big compared with the length. The AISC code requires the length of a fillet weld to be at least 4 times its leg, and otherwise the leg used for strength is reduced to one quarter of the length. The calculator shows this limit.

Does this apply to welds loaded in other directions?

The calculator uses the simple case of a load parallel to the axis of the weld, or the conservative case for any direction. AISC allows a higher strength for welds loaded at an angle, up to 50 % more for transverse welds. Weld groups with eccentric loads need an elastic or instantaneous-centre analysis.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.