Skip to content
Omnikalc

Floor natural frequency calculator: fundamental frequency of a floor beam

Enter the span, the stiffness and the weight per unit length of a floor beam or joist to get the natural frequency, the static deflection and the period, and to check the floor against the usual 8 Hz and 10 Hz limits.

Updated on
Your inputs
ft

Value out of range

psi

Value out of range

in⁴

Value out of range

lb/ft

Value out of range

Results

Natural frequency of the floor

9.46 Hz

Between 8 and 10 Hz: check the comfort criteria
Static deflection under the weight
0.1389 in
Natural period
0.106 s
Frequency from the static deflection (0.18 √(g/Δ))
9.50 Hz

A floor that is strong enough can still vibrate under footsteps. The floor natural frequency calculator gives the fundamental frequency of a joist or beam from its span, its stiffness and its weight, together with the static deflection, the period and a quick check of the comfort limits.

How the calculation works

  • Enter the span of the floor joist or beam and its modulus of elasticity E (about 1,600,000 psi for sawn lumber, 29,000,000 psi for steel).
  • Enter the moment of inertia I of the member and the weight per unit length that it carries: the dead load plus the part of the live load that is likely to be present, for example 10% to 25%.
  • The calculator models the floor as a simply supported beam and computes the fundamental frequency f = π / (2L²) × √(E I g / w).
  • It also gives the static deflection under the weight, the period, and the frequency estimated from the deflection with 0.18 √(g/Δ). The two frequencies should be close.

Example

A joist with a span of 11 ft, E = 1,600,000 psi and I = 98.9 in⁴ carries 66.7 lb/ft. With L = 132 in, w = 5.558 lb/in and g = 386.4 in/s², the frequency is f = π / (2 × 132²) × √(1.6e6 × 98.9 × 386.4 / 5.558) = 9.46 Hz. The static deflection is 5wL⁴ / (384EI) = 0.139 in, the period is 0.106 s, and the check 0.18 √(386.4 / 0.139) gives 9.50 Hz. The floor is just below 10 Hz, so the comfort criteria should be checked.

Why it matters

The calculator helps designers, builders and homeowners to find out if a floor is likely to feel bouncy before it is built, to compare joist sizes and spans, and to see how much a deeper section or a shorter span helps. The frequency is a first screening step before a detailed vibration analysis.

Good to know

Use the real stiffness of the member and the weight that is likely to be present. Remember that the frequency changes with the inverse of the square of the span: reducing the span by 10% raises the frequency by about 23%. Add a stiffer subfloor, blocking or a second beam if the result is below 8 Hz.

The wood beam span calculator sizes lumber members, the beam deflection calculator gives the static deflection, the pendulum calculator covers another natural frequency and the Young’s modulus calculator relates stress and strain.

Frequently asked questions

How is the natural frequency of a floor computed?

For a simply supported beam of uniform section, the fundamental frequency is f = π / (2L²) × √(E I / m), where m is the mass per unit length. With the weight w, m = w / g. The frequency rises with the stiffness EI and falls with the square of the span. A shorter span or a deeper joist raises it quickly, since the moment of inertia goes with the cube of the depth.

What frequency is considered safe for a floor?

There is no single limit. Many guides ask for at least 8 Hz for a floor that supports walking, to keep it away from the frequency of footsteps of about 2 Hz and their harmonics. Offices and homes are often designed for 8 to 10 Hz or more. Quiet places such as laboratories or hospitals can need 15 Hz or more. The comfort also depends on the damping, on the mass, and on the activities.

Why use only part of the live load?

Vibration is a service problem for people who walk on the floor, not an ultimate-strength problem. The live load is rarely at its full design value, so only the dead load and a small part of the live load, such as furniture and people, move with the floor. Using the full design live load would give a lower frequency than the one that is felt.

What are the limits of this calculator?

It gives the fundamental frequency of a single simply supported member. It does not include the continuity over supports, the composite action with a slab, the two-way action of the floor, the damping or the acceleration caused by walking. For sensitive floors, use the design guides for floor vibrations or a finite element model.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.