Guyed mast guy tension calculator: tension in the guy wires of an antenna mast or a pole under wind

Enter the attachment height, the distance to the anchor, the horizontal load, the layout of the guys and the breaking strength to get the guy length, the horizontal component, the tension, the safety factor and the anchor uplift.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

lb

Value out of range

lb

Value out of range

Results

Tension in the guy

3,606 lb

Length of a guy
72.1 ft
Horizontal component in a guy
2,000 lb
Safety factor on the breaking strength
3.33
The safety factor is adequate
Uplift at an anchor
3,000 lb

The guyed mast guy tension calculator gives the tension in the guys of a mast or a pole from the attachment height, the distance to the anchor, the horizontal wind load and the layout of the guys, with the safety factor on the cable and the uplift at the anchor.

How the calculation works

  • Enter the height at which the guys are attached to the mast and the distance from the mast to the anchors on the ground.
  • Enter the horizontal load at the attachment, usually the wind on the mast and the antennas, and choose the layout of the guys.
  • Enter the breaking strength of the guy cable.
  • The calculator finds the length of a guy, the horizontal component that it must carry, its tension, the safety factor on the breaking strength and the uplift at an anchor.

Example

A mast has guys attached at 60 ft, anchored 40 ft from its base, with a wind load of 2,000 lb and three guys at 120°. The wind blows between two guys at ±60°, so each carries a horizontal component of 2,000 / (2 × cos 60°) = 2,000 lb. The guy is √(60² + 40²) = 72.1 ft long, and its tension is 2,000 × 72.1 / 40 = 3,606 lb. With a breaking strength of 12,000 lb the safety factor is 3.33, and the uplift at each anchor is 2,000 × 60 / 40 = 3,000 lb.

Why it matters

The calculator helps antenna installers, radio amateurs, farm and utility workers, riggers and engineers to check the guys of a mast in a first design, to choose a cable and an anchor distance and to see the effect of the layout. It shows why a flatter guy has a lower tension and more room.

Good to know

Make the anchor distance at least half the attachment height, and ideally about 0.7 to 1.0 times, so that the guys are not too steep. Apply the wind to the whole structure including the antennas and the ice. Use a cable and fittings with a margin, check the anchor for the uplift, and follow the standard and the local rules for the structure.

The wire rope capacity calculator gives the strength of a cable, the sling angle calculator gives the tension of a leg that is inclined, the cable sag calculator gives the sag of a cable and the wind load calculator gives the pressure of the wind.

Frequently asked questions

How does a guyed mast work?

A guyed mast is a slender pole or tower that is held upright by cables, the guys, fixed to anchors in the ground. The mast mainly carries a compression, while the guys resist the horizontal loads of the wind. A guy works only in tension, so the guys on the windward side carry the load and the ones on the lee side go slack, and the layout of the guys, usually three or four, makes sure that a guy is well placed for any wind direction.

How is the tension in a guy found?

The horizontal load is shared by the guys that are loaded. For three guys at 120° with the wind between two of them, each takes P / (2 cos 60°) horizontally. The tension of a guy is its horizontal component multiplied by L / D, where L is the length of the guy and D the horizontal distance to the anchor. A flatter guy, with a large D, has a lower tension but needs more space and a longer cable.

What safety factor is used?

The breaking strength of the cable divided by the tension must be at least 2 for the wind of the design, and a factor of 2.5 to 3 is commonly used for the guys of a permanent structure, to take account of the pretension, the ice, the fatigue and the loss of strength at the end terminations. The safety factor of the calculator is given on the breaking strength, not on the working load limit.

What are the limits of the calculator?

The calculator treats a mast with a single level of guys, and considers a static wind load at the attachment and a straight cable. It does not give the compression of the mast, its buckling, the pretension, the sag of the cable, the dynamic effect of the wind, the ice, nor the design of the anchors. The design of a tower with several levels of guys must follow the standard, such as TIA-222, and be made by a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.