Skip to content
Omnikalc

MSE wall calculator: reinforcement tension in a mechanically stabilized earth wall

Enter the height, the layer depth, the backfill properties, the surcharge, the layer spacing and the reinforcement strength to get Ka, the horizontal stress, the tension in the layer, the strength ratio and the minimum length.

Updated on
Your inputs
ft

Value out of range

ft

Value out of range

°

Value out of range

pcf

Value out of range

psf

Value out of range

ft

Value out of range

lb/ft

Value out of range

Results

Reinforcement strength to tension ratio

2.20

Allowable strength is at least the tension in the layer
Active coefficient Ka
0.283
Horizontal stress at the layer
681 psf
Tension per foot of wall in the layer
1,363 lb/ft
Minimum reinforcement length (0.7 H)
14.0 ft

The MSE wall calculator gives Ka, the horizontal stress, the reinforcement tension per unit length of wall, the strength to tension ratio and the minimum length of the reinforcement of a mechanically stabilized earth wall, from the height, the backfill, the surcharge and the layer spacing.

How the calculation works

  • Enter the height of the wall and the depth of the reinforcement layer that you want to check, usually the lowest layer.
  • Enter the friction angle and the unit weight of the reinforced backfill, the surcharge on top and the vertical spacing of the layers.
  • Enter the allowable long-term strength of the reinforcement. The calculator finds Ka, the horizontal stress at the layer, the tension per unit length of wall, the strength to tension ratio and the minimum length of the reinforcement.

Example

An MSE wall is 20 ft high, with a backfill of φ = 34° and 120 pcf, a surcharge of 250 psf and layers spaced 2 ft. At a depth of 18 ft, Ka = 0.283 and the horizontal stress is 0.283 × (120 × 18 + 250) = 681 psf. The tension is 681 × 2 = 1,363 lb/ft. With an allowable strength of 3,000 lb/ft, the ratio is 3,000 / 1,363 = 2.20. The minimum length of the reinforcement is 0.7 × 20 = 14.0 ft.

Why it matters

The calculator helps geotechnical engineers, civil designers, contractors and students to check the reinforcement layers of a geogrid or strip reinforced wall in a first design, and to see how the height, the spacing and the surcharge change the tension.

Good to know

Use a free draining granular backfill with a friction angle given by the tests, and use the long-term design strength of the reinforcement, not the ultimate strength. Check the pullout, the connection and the stability of the whole mass, and design the drainage behind and under the reinforced zone.

The retaining wall calculator checks a gravity wall, the retaining wall stem design calculator sizes a concrete stem, the Rankine earth pressure calculator gives Ka and the soil nail pullout calculator checks another type of reinforcement.

Frequently asked questions

What is an MSE wall?

A mechanically stabilized earth (MSE) wall is a retaining wall made of compacted granular soil reinforced with horizontal layers of steel strips, steel grids or geosynthetics (geogrids or geotextiles), with a facing of precast panels or blocks. The reinforcement takes the tension that the soil cannot carry, and the soil mass behaves like a gravity wall. These walls are flexible, economical for heights of 10 to 50 ft, and resist the earthquakes well.

How is the tension in a layer found?

With the simple coefficient method, the horizontal stress at a depth z is σh = Ka (γ z + q), where Ka is the Rankine active coefficient of the reinforced backfill and q the surcharge. Each layer takes the stress over its tributary height, which is the vertical spacing. The maximum tension per unit length of wall is then Tmax = σh Sv. The layers near the bottom of the wall have the highest tension.

What length of reinforcement is needed?

The length of the reinforcement is usually at least 0.7 times the height of the wall, and at least 8 ft (2.5 m). It must be long enough to give the pullout resistance beyond the failure surface and the stability against the sliding and the overturning of the mass, so it is often 0.7 to 1.0 H, or more with a heavy surcharge, a slope on top or a soft foundation.

What are the limits of the calculator?

The calculator finds only the tension in one layer. It does not check the pullout of the reinforcement, the connection to the facing, the internal and external stability, the bearing capacity, the settlement, the water or the seismic loads. For the steel reinforcement, the stiffness is different and the stress is higher near the top. The design should follow the FHWA or the AASHTO guide with a qualified engineer.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.