Hydraulic accumulator sizing calculator: size, precharge and pressure ratio

Enter the fluid volume needed, the minimum and maximum pressures and the gas precharge to get the size of a bladder or piston accumulator, the gas volume at full pressure and the pressure ratio.

Updated on
Your inputs
gal

Value out of range

psi

Value out of range

psi

Value out of range

psi

Value out of range

Value out of range

Results

Accumulator size (gas volume at precharge)

5.67 gal

Gas volume at the maximum pressure
3.12 gal
Pressure ratio p2 / p1
2.00
Ratio within the usual limit of 4
Precharge as a share of the minimum pressure
86.7%
Precharge between 80 and 90% of the minimum pressure

A hydraulic accumulator stores fluid under pressure by compressing a gas. The accumulator sizing calculator gives the size that supplies a given volume of fluid between a minimum and a maximum pressure, with the gas precharge and the speed of the discharge, and checks the pressure ratio.

How the calculation works

  • Enter the fluid volume that the accumulator must deliver between the maximum and the minimum pressure.
  • Enter the minimum and the maximum system pressure, and the gas precharge pressure, which should be 80 to 90% of the minimum pressure.
  • Enter the gas exponent: 1.4 for a fast discharge (adiabatic, less than a minute) and 1.0 for a slow one (isothermal), and about 1.2 between them.
  • The calculator applies the gas law p V^n = constant and gives the size of the accumulator, the gas volume at the maximum pressure, the pressure ratio and the precharge share.

Example

A system needs 2 gal of fluid between 1,500 psi and 3,000 psi, with a precharge of 1,300 psi and a fast discharge (n = 1.4). The gas fills the accumulator at the precharge, and compresses to p1 and p2. The size is V0 = 2 / ((1,300 / 1,500)^(1/1.4) − (1,300 / 3,000)^(1/1.4)) = 2 / (0.9031 − 0.5503) = 5.67 gal. At the maximum pressure, the gas takes 3.12 gal. The pressure ratio is 2.0 and the precharge is 86.7% of the minimum pressure, both in the good range.

Why it matters

The calculator helps hydraulic designers, maintenance technicians and students to choose an accumulator for a press, a brake circuit, a pulsation damper or an emergency supply. It also shows how the precharge and the discharge speed change the size, which a catalog table does not.

Good to know

Enter absolute pressures: add the atmospheric pressure (14.7 psi or about 1 bar) to the gauge values for an accurate result, especially at low pressures. Keep the pressure ratio below 4 for a bladder accumulator. Add 10 to 20% to the volume as a margin, and follow the safety rules for pressure vessels, with a relief valve and a discharge valve.

The combined gas law calculator relates pressure, volume and temperature of a gas, the hydrostatic pressure calculator gives the pressure of a column of fluid, the pump power calculator sizes the pump and the ideal gas calculator covers the gas.

Frequently asked questions

How does a hydraulic accumulator work?

A hydraulic accumulator stores fluid under pressure by compressing a gas, usually nitrogen, in a bladder, a piston or a diaphragm. When the pressure of the system falls, the gas expands and pushes fluid out. It is used to supply peak flows, to absorb pressure shocks, to damp the pulsations of a pump and to keep the pressure when the pump is off or in an emergency.

What is the formula for the size?

The gas follows p V^n = constant. The volume of fluid delivered between p2 and p1 is the difference of the gas volumes at these pressures, V1 − V2, with V1 = V0 (p0 / p1)^(1/n) and V2 = V0 (p0 / p2)^(1/n). Solving gives V0 = ΔV / ((p0 / p1)^(1/n) − (p0 / p2)^(1/n)), where p0 is the precharge pressure, and all the pressures are absolute.

What precharge should I use?

The usual rule is a precharge of 80 to 90% of the minimum working pressure for an energy storage use, and 60 to 80% for pulsation damping. If the precharge is equal to or above the minimum pressure, the accumulator is empty at that pressure and there is no usable volume. A low precharge wastes volume. Check the precharge every few months, since the gas diffuses.

Why does the speed of the discharge matter?

In a fast discharge, the gas has no time to exchange heat with the walls and it follows the adiabatic law with n = 1.4 for nitrogen, so the pressure falls more and the usable volume is less. In a slow discharge, it follows the isothermal law with n = 1.0 and the usable volume is larger. Use n = 1.4 for the safe size, and enter absolute pressures (gauge plus atmosphere) for an accurate result.