Force main calculator: head loss and pump head of a pressurized sewer line

Enter the pumping rate, the diameter, the length, the Hazen-Williams C and the static lift to get the velocity, the friction head loss, the total dynamic head of the pump and the detention time in the pipe.

Updated on
Your inputs
gpm

Value out of range

in

Value out of range

ft

Value out of range

ft

Value out of range

Results

Total dynamic head of the pump

49.9 ft

Velocity in the pipe
2.27 ft/s
Velocity in the usual range of 2 to 8 ft/s
Friction head loss
9.86 ft
Detention time in the pipe
36.7 min

The force main calculator gives the velocity, the friction head loss by the Hazen-Williams formula, the total dynamic head that the pump must supply and the detention time of the wastewater in a pressurized sewer line, from the flow, the diameter, the length and the static lift.

How the calculation works

  • Enter the pumping rate, the inside diameter and the length of the force main.
  • Choose the Hazen-Williams C of the pipe material and condition, and enter the static lift between the wet well and the discharge point.
  • The calculator finds the velocity, the friction head loss with the Hazen-Williams formula, the total dynamic head to be supplied by the pump and the detention time of the sewage in the pipe.

Example

A pump station delivers 800 gpm through 5,000 ft of 12 in force main with C = 120 and a static lift of 40 ft. The velocity is 0.4085 × 800 / 12² = 2.27 ft/s. The friction head loss is 10.4656 × 5,000 × 800^1.852 / (120^1.852 × 12^4.8655) = 9.86 ft, so the total dynamic head is 40 + 9.86 = 49.9 ft. The volume of the pipe, 29,375 gal, is renewed in 36.7 min.

Why it matters

The calculator helps civil and sanitary engineers, utility staff, developers and students to size a force main and a pump in a first design, to compare pipe diameters and to check the velocity and the detention time. A larger pipe lowers the head loss but also lowers the velocity and increases the detention time.

Good to know

Check the velocity at the lowest and the highest pumping rates, and the detention time at the average flow of the first years. Add the minor losses and a margin for the aging of the pipe, with a lower C. Provide air release valves at the high points, drain valves at the low points, and analyze the surge when the pumps stop.

The friction loss calculator gives the head loss of any pipe, the pump power calculator gives the power of the pump, the wet well volume calculator sizes the lift station and the pipe flow velocity calculator converts the flow to a velocity.

Frequently asked questions

What is a force main?

A force main is a pressurized sewer pipe that carries wastewater from a lift station, pumped from the wet well, to a point of higher elevation or to a treatment plant. Unlike a gravity sewer, it flows full under the pressure of the pump. Its design must give a velocity that keeps the solids moving, a head loss that the pump can overcome, and a detention time short enough to avoid septic conditions.

How is the head loss found?

The calculator uses the Hazen-Williams formula in US units, hf = 10.4656 L Q^1.852 / (C^1.852 d^4.8655), with the length in feet, the flow in gpm and the diameter in inches. The coefficient C depends on the material and the age of the pipe, from 100 for an old rough pipe to 140 for new plastic. The total dynamic head of the pump is the static lift plus the friction losses, plus the minor losses in the fittings, which are added separately.

What velocity should a force main have?

A minimum velocity of 2 ft/s (0.6 m/s) is recommended at least once a day, to resuspend the solids that settle when the pump is off. Velocities above 8 ft/s (2.4 m/s) give high losses and increase the risk of surge. When the main is long, the sewage stays in the pipe for hours, becomes septic and produces hydrogen sulfide, which corrodes the downstream concrete pipes and manholes, so the detention time matters.

What are the limits of the calculator?

The calculator gives the steady flow losses in the pipe only. It does not include the minor losses, the pump curve, the surge pressure when the pump stops, the air in the high points, the variation of C with age, or the multiple pump operation. The design of a lift station and its force main must be made by a qualified engineer.