The force main calculator gives the velocity, the friction head loss by the Hazen-Williams formula, the total dynamic head that the pump must supply and the detention time of the wastewater in a pressurized sewer line, from the flow, the diameter, the length and the static lift.
How the calculation works
- Enter the pumping rate, the inside diameter and the length of the force main.
- Choose the Hazen-Williams C of the pipe material and condition, and enter the static lift between the wet well and the discharge point.
- The calculator finds the velocity, the friction head loss with the Hazen-Williams formula, the total dynamic head to be supplied by the pump and the detention time of the sewage in the pipe.
Example
A pump station delivers 800 gpm through 5,000 ft of 12 in force main with C = 120 and a static lift of 40 ft. The velocity is 0.4085 × 800 / 12² = 2.27 ft/s. The friction head loss is 10.4656 × 5,000 × 800^1.852 / (120^1.852 × 12^4.8655) = 9.86 ft, so the total dynamic head is 40 + 9.86 = 49.9 ft. The volume of the pipe, 29,375 gal, is renewed in 36.7 min.
Why it matters
The calculator helps civil and sanitary engineers, utility staff, developers and students to size a force main and a pump in a first design, to compare pipe diameters and to check the velocity and the detention time. A larger pipe lowers the head loss but also lowers the velocity and increases the detention time.
Good to know
Check the velocity at the lowest and the highest pumping rates, and the detention time at the average flow of the first years. Add the minor losses and a margin for the aging of the pipe, with a lower C. Provide air release valves at the high points, drain valves at the low points, and analyze the surge when the pumps stop.
Related tools
The friction loss calculator gives the head loss of any pipe, the pump power calculator gives the power of the pump, the wet well volume calculator sizes the lift station and the pipe flow velocity calculator converts the flow to a velocity.