Skip to content
Omnikalc

Joint sealant calculator: width and depth of a movement joint from the thermal movement

Enter the joint spacing, the temperature range, the material and the movement capability of the sealant to get the movement, the minimum and recommended width, the depth and the sealant quantity.

Updated on
Your inputs
ft

Value out of range

°F

Value out of range

Results

Recommended joint width (to the next 1/8 in)

0.375 in

Movement of the joint
0.079 in
Minimum joint width
0.317 in
Depth of the sealant
0.250 in
Sealant per 100 ft of joint
0.49 gal

The joint sealant calculator gives the movement of the joint, the minimum width, the recommended width, the depth of the sealant and the quantity of sealant for a movement joint, from the joint spacing, the temperature range, the material and the movement capability of the sealant.

How the calculation works

  • Enter the joint spacing, which is the length of the panel between two joints, and the temperature range of the panel.
  • Choose the material for the coefficient of expansion and the movement capability of the sealant.
  • The calculator finds the movement of the joint, the minimum width, the recommended width, the depth of the sealant and the quantity per 100 ft.

Example

A concrete panel with joints every 15 ft has a temperature range of 80 °F. The movement is 15 × 12 × 5.5 × 10⁻⁶ × 80 = 0.079 in. A sealant of ±25 % needs a minimum width of 0.079 / 0.25 = 0.317 in, so the recommended width is 3/8 in (0.375 in). The depth is half of the width but not less than 0.25 in, so it is 0.250 in. The sealant for 100 ft is 0.375 × 0.25 × 1,200 / 231 = 0.49 gal.

Why it matters

The calculator helps façade and flooring contractors, architects, building envelope specifiers and students to size the joints of a concrete, masonry or metal panel, to check that a sealant can take the movement and to estimate the quantity to order.

Good to know

Use the temperature range of the site and the real size of the panel, and add the shrinkage for the new concrete. Install a backer rod of the right diameter, apply the primer if the data sheet asks for it and tool the sealant to give a good contact with the sides. Do not fill the joint in the coldest or hottest part of the day, because the joint is then at the extreme of its movement.

The concrete sealer calculator estimates a sealer for a surface, the slab joint spacing calculator gives the spacing of the saw cuts, the bridge expansion joint movement calculator handles the long structures and the concrete crack width calculator checks the cracks.

Frequently asked questions

How is the movement of a joint calculated?

The thermal movement is the length of the panel times the coefficient of thermal expansion of the material times the temperature range. For a concrete panel of 15 ft and a range of 80 °F, the movement is about 0.08 in. The movement of the joint can be increased by the shrinkage, the creep and the moisture movement, which are added for the new concrete and the masonry.

How is the width of the joint chosen?

The width of the joint is the movement divided by the movement capability of the sealant, expressed as a ratio. A sealant of ±25 % can stretch or compress by 25 % of the width of the joint in service. Many designers round the width up to the next 1/8 in and use at least 1/4 in, because a narrow joint is difficult to fill and to keep clean.

What depth should the sealant have?

The depth of the sealant is generally half of the width of the joint for a width up to 1/2 in, with a minimum of 1/4 in, and a depth of 1/2 in for a wider joint. The backer rod under the sealant controls the depth and prevents the adhesion at the bottom of the joint, so the sealant can stretch as a thin hourglass. A sealant that is too deep is stressed and fails.

What are the limits of the calculator?

The calculator gives the thermal movement for a free panel and does not include the shrinkage, the creep, the structural movement, the shear movement, the construction tolerances, the temperature at the time of the installation or the needs of the specific sealant. Read the data sheet of the sealant, which gives the limits of the width and the depth, the primer, the backer rod and the temperature of the installation.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.