The bridge expansion joint movement calculator gives the movement that an expansion joint must allow from the length of the deck, the material, the temperature range and the shrinkage and creep strain, with the design movement and the type of joint that it calls for.
How the calculation works
- Enter the length of the deck that moves toward the joint, measured from the fixed point (the pier or abutment that holds the deck) to the joint.
- Choose the material of the superstructure and enter the design temperature range, from the lowest to the highest temperature of the deck.
- Enter the shrinkage and creep strain for a concrete deck (for steel, 0) and a factor for the construction tolerance.
- The calculator finds the thermal movement, the shrinkage and creep movement, the total and the design movement of the joint.
Example
A concrete deck of 300 ft moves toward a joint, with a temperature range of 100 °F. The thermal movement is 6.0 × 10⁻⁶ × 300 × 12 × 100 = 2.16 in. A shrinkage and creep strain of 200 με adds 0.0002 × 300 × 12 = 0.72 in, for a total of 2.88 in. With a factor of 1.3 the design movement of the joint is 3.74 in, which calls for a strip seal or a finger joint.
Why it matters
The calculator helps bridge engineers, civil designers, inspectors and students to estimate the movement of a joint in a first design, to choose between a compression seal, a strip seal, a finger joint or a modular joint and to see the effect of the length of the deck. It shows why long bridges are divided into several spans with joints.
Good to know
Use the temperature range of the bridge code for the location and the type of bridge, and the shrinkage and creep from the structural analysis. Set the joint opening for the temperature at the time of installation. Provide drainage under the joint, and inspect it regularly, because the failed joints are a major cause of the damage of the bearings and the piers.
Related tools
The pipe expansion loop calculator covers the thermal expansion of pipes, the thermal expansion calculator gives the change of length of any bar, the slab joint spacing calculator covers the joints of the slabs and the prestressed beam stress calculator covers the prestressed girders.