The noise barrier calculator gives the path difference, the Fresnel number and the insertion loss in decibels of a wall between a noise source and a receiver, and the sound level behind it.
How the calculation works
- Enter the heights of the noise source, the receiver and the top of the barrier, and the distances from the barrier to the source and to the receiver.
- Enter the frequency of the noise and the sound level at the receiver without the barrier.
- The calculator gives the path difference, the Fresnel number, the insertion loss and the sound level behind the barrier.
Example
A truck exhaust at 8 ft is 40 ft from a barrier whose top is at 14 ft, and a receiver with ears at 5 ft stands 100 ft behind it. The sound that goes over the top travels 0.82 ft farther than the straight line, so at 500 Hz the Fresnel number is N = 2 δ f / c = 0.73. The insertion loss is 10 log10(3 + 20 N) = 12.4 dB, and a level of 72 dBA without the barrier drops to 59.6 dBA behind it.
Why it matters
The calculator helps acoustic consultants, highway and site engineers, contractors and neighbors to see what a barrier of a given height does, to compare heights and positions, and to check that a wall reaches the reduction that a permit or a noise limit requires.
Good to know
Put the barrier close to the source or close to the receiver, because the path difference is largest there. Keep the wall free of gaps, with sealed joints and a closed base, and make it heavy enough to block the sound that goes through it. A reduction of 5 dB is noticeable, 10 dB sounds half as loud, and more than 15 dB is hard to reach with a simple wall. A second check of the barrier at low and high frequencies shows how sensitive the result is.
Related tools
The insertion loss calculator treats a filter in a circuit, the sound transmission class calculator rates the wall itself, the critical distance calculator compares direct and reverberant sound in a room and the noise exposure calculator gives the daily dose of a worker.