Skip to content
Omnikalc

Pile driving formula calculator: pile capacity from the driving record

Enter the hammer type, the weight of the ram, the drop height, the set per blow and the safety factor to get the energy per blow, the ultimate pile capacity by the ENR formula, the allowable load and the blows per foot.

Updated on
Your inputs
lb

Value out of range

ft

Value out of range

in

Value out of range

Value out of range

Results

Allowable pile load

5,333 lb

Energy of the hammer per blow
20,000 ft·lb
Ultimate pile capacity (ENR)
32,000 lb
Ultimate pile capacity (ENR)
16.0 tons
Blows per foot of penetration
48

The way a pile goes into the ground tells how much it can carry. The pile driving formula calculator applies the Engineering News Record (ENR) equation to the hammer weight, the drop height and the set per blow to give the ultimate capacity, the allowable load and the blows per foot of the driving record.

How the calculation works

  • Select the hammer type: a drop hammer, or a steam or air hammer. The formula adds 1 in to the set for a drop hammer and 0.1 in for a steam hammer, to account for the energy lost in the cap and in the compression of the pile.
  • Enter the weight of the ram, the height of the drop and the set: the average penetration of the pile for the last blows, in inches per blow.
  • Enter the safety factor, usually 6 for the ENR formula, which is known to be unconservative.
  • The calculator applies the Engineering News Record (ENR) formula Qu = 2 W h / (s + c) and gives the ultimate capacity, the allowable load and the blows per foot to expect at that set.

Example

A drop hammer with a ram of 5,000 lb falls 4 ft and drives a pile with a set of 0.25 in per blow. The energy is 20,000 ft·lb. The ultimate capacity is 2 × 5,000 × 4 / (0.25 + 1) = 32,000 lb, or 16 tons. With a safety factor of 6, the allowable load is 5,333 lb. The driving record is 48 blows per foot.

Why it matters

The calculator helps foundation contractors, inspectors, engineers and students to read the driving record of a pile, to decide what set is needed for a given load and to understand the principle of dynamic formulas. It is a practical on-site check.

Good to know

Use the formula only to compare piles of the same type on the same site, and to find the set that gives the design load. Confirm with a load test on one or more piles. Do not apply it to piles driven in clay with a high water pressure, or when the hammer is not working well. Record the blows per foot for the whole length.

The pile capacity calculator gives the static capacity from the soil, the bearing capacity calculator covers shallow foundations, the footing size calculator sizes the footings and the settlement calculator estimates the movement.

Frequently asked questions

What is a dynamic pile formula?

A dynamic formula estimates the capacity of a driven pile from the way it penetrates when the hammer hits it. The energy of the hammer is used to push the pile into the soil by the set s, so the soil resistance is about the energy divided by the set. The more the pile resists, the less it penetrates for each blow. These formulas are used on site to check the piles, since the driving record is available for each pile.

What is the ENR formula?

The Engineering News Record formula is among the oldest: Ru = 2 W h / (s + c), with W the weight of the ram, h the drop, s the set per blow and c a constant of 1 in for a drop hammer and 0.1 in for a steam hammer. The factor 2 and the constant c come from experience. With a safety factor of 6, it gives the allowable load. The ENR formula is simple but very rough, and it can be wrong by a large amount.

Why is the safety factor so high?

The dynamic formulas have a large scatter compared with static load tests, because they ignore the weight of the pile, the stress waves, the soil damping and the time-dependent changes of the soil, such as the gain of strength after driving in clay or the relaxation in dense silts. A factor of 6 for the ENR formula is the traditional compensation. Modern projects prefer the wave equation analysis and the load tests.

What are the limits of this calculator?

It is a rough check that is not enough for design. It does not include the weight of the pile and of the cap, the efficiency of the hammer, the elastic compression of the pile and the soil, the length and the material of the pile or the group effects. Use it to compare piles on one site and to spot a problem, and confirm the capacity with a load test or a dynamic test according to the code.

Was this calculator helpful?

Thanks for your feedback!

Results are estimates provided for information purposes. They do not replace professional advice.