The axial capacity of a pile in clay comes from the friction on its sides and the bearing of its tip. The pile capacity calculator uses the alpha method with the undrained shear strength of the clay to give the shaft resistance, the end bearing, the ultimate capacity and the allowable load.
How the calculation works
- Enter the diameter of the pile and its embedded length in the clay.
- Enter the undrained shear strength of the clay, from the soil report, and the adhesion factor α (about 1.0 for soft clay and 0.5 for stiff clay).
- The calculator computes the shaft resistance α × su × perimeter × length and the end bearing 9 × su × area of the tip.
- It adds them into the ultimate capacity and divides by the factor of safety to give the allowable capacity.
Example
A pile of 18 in diameter is driven 40 ft into a clay with su = 1,500 psf and α = 0.55. The perimeter is 4.71 ft, so the shaft resistance is 0.55 × 1,500 × 4.71 × 40 = 155.5 kips. The tip area is 1.77 ft², so the end bearing is 9 × 1,500 × 1.77 = 23.9 kips. The ultimate capacity is 179.4 kips, of which 87 % comes from the shaft, and with a factor of safety of 2.5 the allowable capacity is 71.7 kips.
Why it matters
The calculator helps civil engineering students, foundation contractors and engineers to get a first estimate of the length or the diameter of a driven or bored pile in clay, to see how much of the load is carried by the shaft and by the tip and to compare options before the geotechnical design.
Good to know
The calculator gives a static estimate for a single pile in homogeneous clay under compression. It does not consider layered soils, group effects, negative skin friction, settlement, lateral loads, uplift, the strength of the pile itself or the local code. The adhesion factor and the strength must come from a soil investigation. Use the result for a first estimate only.
Related tools
The bearing capacity calculator covers shallow footings, the retaining wall calculator checks a wall against sliding and overturning, the punching shear calculator checks a slab around a column, and the section modulus calculator is used to check the pile or beam section.