The pipe leakage test calculator gives the allowable leakage per hour, the allowable leakage for the test, the allowable leakage per 1,000 ft and the ratio of the make-up water to the allowable for a hydrostatic test of a pressure pipe, from the length, the diameter and the test pressure.
How the calculation works
- Enter the length of the pipe section tested, its nominal diameter and the average test pressure.
- Enter the duration of the test and the make-up water that was added to hold the pressure.
- The calculator finds the allowable leakage per hour and for the test, per 1,000 ft, and the ratio of the make-up water to the allowable.
Example
A pressure pipe of 12 in is tested over 2,500 ft at an average pressure of 150 psi. The allowable leakage is 2,500 × 12 × √150 / 148,000 = 2.48 gal/h, or 0.99 gal/h per 1,000 ft. For a test of 2 h, the allowable leakage is 4.97 gal. If 3.5 gal of make-up water was added, the ratio is 3.5 / 4.97 = 0.70, which passes the test.
Why it matters
The calculator helps pipeline contractors, inspectors, utility engineers and students to prepare the acceptance test of a new water main, to judge if the make-up water measured is acceptable and to compare the allowance for different lengths and diameters.
Good to know
Fill the line slowly from the low point with the air vents open, and let the pipe soak so that it is full of water before the test. Bleed all the air, bring the pressure up and hold it, and measure the make-up water with a calibrated meter or a graduated tank. Block the pipe ends and the valves with restraints that can take the test pressure, and keep the people away from the line during the test.
Related tools
The hydrostatic test pressure calculator gives the pressure of the test, the pipe wall thickness calculator checks the pipe, the thrust block size calculator restrains the fittings and the leak rate pressure rise calculator handles the leaks in a closed volume.