The Scruton number calculator gives the Scruton number, a vibration risk class, the critical wind speed for vortex shedding and the damping ratio or mass per length needed to reach a target value, for a chimney, a mast or any slender cylinder.
How the calculation works
- Enter the mass per unit length, the damping ratio and the outer diameter.
- Enter the natural frequency of the mode, the Strouhal number and the air density.
- Enter a target Scruton number to see the damping or mass required.
Example
A structure of 400 lb/ft with a damping of 0.5 % and a diameter of 6.5 ft has a Scruton number of 7.78, class 1. At 1.2 Hz the critical wind speed is 39.0 ft/s, or 26.6 mph. To reach a Scruton number of 10, it would need a damping of 0.64 % or a mass of 514 lb/ft.
Why it matters
The calculator helps structural and wind engineers, students and designers of steel stacks, light poles, antennas, masts and tubular towers who must decide early whether a slender cylinder needs strakes, a damper or a change of mass before a detailed aeroelastic study.
Good to know
Use the damping ratio of the structure in the mode considered, not the logarithmic decrement, and consistent units: pounds per foot, pounds per cubic foot and feet in the US version, kilograms per meter, kilograms per cubic meter and meters in the metric version. The risk classes are a rough reading, since each standard has its own limits and procedures. Lock-in can also occur at higher modes, with ice or with neighboring structures. A wind tunnel test or the applicable standard should confirm important designs.
Related tools
The damping ratio calculator explains how damping is measured, the tuned mass damper calculator sizes a damper to add damping, the Reynolds number calculator characterizes the flow around the cylinder and the wind load calculator gives the static wind force.